36
doi :10.3969/j. issn, 1009 3230.2018.06.010
应用能源技术
2018年第6期(总第246期)
浅析无人值守技术在供热系统的设计及应用
谷幸,颜翔翎
(1.石家庄华电供热集团有限公司,石家庄050000: 2.河北华电石家庄裕华热电有限公司,石家庄050041)
摘要:结合石家庄华电智能热网的应用情况,对无人值守技术的组织架构及控制原理做了介绍。通过采用变频技术,大流量小温差运行,能够优化单站运行指标,节能降耗,取得了良好的社会和经济效益。
关键词:无人值守;变频;节能
中图分类号:TU833.1文献标志码:B文章编号:1009-3230(2018)06-0036-02
AnalysisofDesignandApplicationof Unattended
Technology in theHeating System
GUXing,YANXiang-ling
(1. Shijiazhuang Huadian Heating Group Co.,Ltd. Shijiazhuang 050000, China;
2. Hebei Huadian Shijiazhuang Yuhua Thermal Power Co.,Ltd. Shijiazhuang 050041, China) Abstract:Based on the application of Shijiazhuang Huadian intelligent heat network, introducing the organization structure and control principle of the unattended technology. Through using frequency conversion technology , large flow and small temperature difference operation, it can optimize the operation index of single
station, save energy and reduce consumption, and achieve good social and economic benefits. Key words: Unattended; Frequency conversion; Energy saving
0引言
集中供热是国家能源合理分配利用的有效形式,具有节能降耗,提高能源利用率,消除烟尘,降低大气污染等优点。目前换热站管理大都采用人工管理,效率低,成本高。同时各站独立运行,加上热网调节大延迟,高滞后的特点,难以达到全网水力平衡的最佳状态。我单位自2012年开始实施基于西门子PVSS系统的智能热网项目,对一次网实现了按流量、按温度的自控调节,取得了较为理想的控制效果。随着省会“一管到户’政策的实施,接管热用户的数量持续增多,为了深挖热网供热潜力,进一步发挥节能降耗的优势,建立高标准无人值守换热站,我公司自2016年起实施二级网变频改造项目。
收稿日期:2018-0328
修订日期:201804-29
作者介:谷幸(1986-),男,硕士研究生,河北定州人,
石家庄华电供热集团
万方数据
1工作站控制系统
工作站控制系统是整个智能热网的核心部分,由三个操作员站、两个工程师站、四台PVSS 服务器、两台Oracle数据库服务器和一台磁盘阵列服务器构成,用来实现远程监控。系统能够监测换热站主要运行参数,并选择最优控制方式。系统基于西门子PVSS客户机V服务器结构,为优化管理采用扁平化对等数据结构
基本功能如下:(1)监控功能,监控系统可远程更新采集程序、发送启动和停止采集数据命令,能够控制一次网电调阀开度和二次网变频器状态;(2)数据分析处理功能,接收并解析现场PLC发送的数据包,分析处理后以数字或者图表形式展现给操作人员:(3)报警功能,当某一参数超出预设值、设备状态发生变化或意外事故时,系统自动提供声光报警,并支持报警信息打即及分类存储,由用户动态增删修改报警目标、对象及阔值,同时提供灵活的查询方式