(Harbin Hatou Investment Co.,Ltd.Heat Supply Compamy,Harbin 150090, China) Abstract: In view of the heating system water power being out of balance question, proposed for the thorough settlement water power being out of balance condition by-pass valve's function, introduced by-pass valve's classification and the characteristic, the valve discharge coefficients computation and the by-pass valve selected, explained by-pass valve' s installment position and the matters needing attention, showed installs economical energy conservation benefit which the by-pass valve brought. Key words: Heating system; Water power being out of balance; By-pass valve; Discharge coeffi cient
0前言
近年来,随着我国经济的快速发展、人民生活质量的不断提高,城市的建筑规模越来越大,现代化的大型住宅小区和大型商业贸易区的建立,扩网增容的现象极为普遍,集中供热事业发展迅速。由于供热规模迅速扩大,供热系统中的水力失调现象变得尤为突出。因为水力失调的影响,部分热用户达不到用暖标准,系统中“近热远冷”现象较为严重。为了解决水力失调问题,许多设计人员或运行管理人员往往采用加大锅炉容量和循环水泵流量的方法来缓解矛盾,这种“大大流量、小温差”的运行方式并不能从根本上解决水力失调问题,却导致工程投资增加,运行费用增大,造成了大量的能源浪费。
收稿日期:201004-11
修订日期:2010-0429
作者简介:尹瑾露(1973-),男,现就职于哈尔滨哈投投资
股份有限公司供热公司,担任工程技术科科长,主要从事工程技术、施工及管理工作。
万方数据
29
随着节能要求的不断提高,准确调节流量已
受到用户和管理部门的高度重视。平衡阀是供热管网中调节水力工况的重要方式之一,科学的应用平衡阀解决供热管网中的水力失调问题,将会取得显著的节能效益。这在当前我国建筑节能呼声日益强烈、世界性的能源日趋紧张的形式面前,具有重要意义。同时平衡阅的合理应用也给供热管网的运行及管理带来了极大方便。
水力失调及水力平衡概念及分类管道水力失调一般分为静态失调和动态失调
两种。
1.1静态水力失调和静态水力平衡
静态水力失调:是由于设计、施工、设备材料等原因导致的系统管道特性阻力数比值与设计要求管道特性阻力数比值不一致,从而使系统各用户的实际流量与要求流量不一致,引起的水力失调。这种水力失调是根本性的,如不加以解决,影