第45卷第5期 2017年5月
聚氯乙烯 Polyvinyl Chloride
原子吸收光谱法测量PVC中的Fe含量
陈万银',郑伟玲,谢东阳,司江坤
(新疆兵团现代绿色氯碱化工工程研究中心(有限公司),新疆石河子832000)
[关键词】原子吸收光谱;PVC;Fe含量
Vol.45,No.5 May,2017
【摘要】对PVC树脂样品进行焙烧及盐酸清洗预处理,运用原子吸收光谱仪测定其Fe含量。指出采用原子吸收光谱法测量PVC中的Fe含量具有操作简单、准确度高的特点。
[中图分类号】TQ325.3;TQ014
【文献标患码】B
【文章编号】10097937(2017)05003703
ThedeterminationofFecontentinPvCbyatomicabsorptionspectroscopy
CHEN Wanyin,ZHENG Weiling,XIE Dongyang,SI Jiangkun(Xinjiang Production and Construction Corps.Modern Green
Chlor Alkali Chemical Engineering Research Center (Ltd.),Shihezi 832000,China)) Key words; atomic absorption spectroscopy;PVC; iron content
Abstract: Samples of PVC resins were pretreated by calcination and cleaning with hydrochloric acid, and Fe content in them was determinated by atomic absorption spectroscopy. It was indicated that atomic absorption spectroscopy had characteristics of simple operation and high accuracy in determination of Fe content in PVC.
PVC树脂是五大通用树脂之一,广泛应用于工业、农业、医疗等领域。据研究,PVC产品的Fe含量偏高易破坏其稳定性,影响其外观质量;对于医用 PVC来说,Fe离子含量偏高是PVC树脂粒料颜色发黄的主要原因,对树脂的使用产生不良影响1]。准确检测PVC树脂中的Fe含量,并在生产过程中加以控制,是保证PVC树脂品质的重要手段之-。
原子吸收光谱法是一种常用的元索含量分析方法,原子吸收光谱仪具有灵敏度高、检测限低的特点,适用于多种金属元素的定量分析。笔者以检测 PVC中的Fe含量为目的,对不同厂家生产的不同型号的PVC树脂进行焙烧及酸化前处理,并配制成一定浓度的溶液,利用原子吸收光谱法对溶液中的
Fe浓度进行检测,以计算树脂中的Fe含量。 1试验部分
1.1主要仪器与试剂
(1)主要仪器。
原子吸收光谱仪(PerkinElemerAanalyst800),,【收稿日期]2017-02-27
Fe空心阴极灯(北京有色金属研究总院),高温箱式电阻炉(南京博蕴通仪器科技有限公司)。
(2)试剂。
Fe标准溶液,1000μg/mL,符合GSB04 1715一2004,国家钢铁研究院;优级纯盐酸溶液,质量分数36.5%,国药集团化学试剂有限公司;高纯乙炔钢瓶气,体积分数>99%,符合GB6819
2004,乌鲁木齐康迪气体公司。 1.2仪器条件
Fe空心阴极灯波长248.3nm,狭缝0.7L,灯电
流25mA,灯实时能量25~26。 1.3样品处理
预先将垢用质量分数30%的优级纯盐酸溶液浸泡4h,再用去离子水漂洗3次以上,于120℃ 烘干,备用。用万分之一天平分别称取3种不同厂家生产的不同类型PVC树脂样品(样品1代号 7.24.样品2代号C-62,样品3代号7.29)约3g 于中,置于马弗炉中程序升温脱氯、挥发、灰化。程序升温过程见表1,焙烧结果见图1。
【作者简介】陈万银(1982一),男,工程师,2006年毕业于湖北长江大学,现于新疆兵团现代绿色氯城化工工程研究中
心(有限公司)从事催化剂研发工作。
37
万方数据