2012年第10期
东北电力技术
汽轮机汽门严密性试验方法探讨与实践
许天宁,郭健,刘勇奇
47
(1.辽宁省电力有限公司电力科学研究院,辽宁沈阳110006;2.大唐锦州热电有限公司辽宁锦州121017)摘要:对汽轮机汽门严密性试验方法进行了探讨,并对合格转速计算公式进行分析和修正,根据修正后的计算公式和试验方法对大店锦州热电有限公司2号汽轮发电机组进行了试验,证明方法及计算公式合理,达到节能效果,同时提高了试验
的安全性,为其它再热机组的使用提供借鉴。关键调:汽轮机;汽门;严密性试验
[中图分类号]TK263[文献标志码]A[文章编号]】1004-7913(2012)10-004703
New Method for Steam Turbine Valve Leak Test
XU Tian-ning',GUO Jian,LIU Yong-qi?
(1. Electric Power Research Institute of Liaoning Electrie Power Co. , Lad. , Shenyang, Liaoning 110006, China;
2. Datang Jinzhou Thermal Power Co. , Lid. , Jinzhou, Liaoning 121017, China)
Abstract: This paper makes discussion on the steam turbine valve leak test methods, and recommend a new formula of calculation and test methods, aceording to the newly recommended calculation formula and test methods in No. 2 steam turbine generator unit test for Datang Jinzhou Thermal Power Co. , Lid. The experiment shows the method is feasible, and improves the safety of the test and can be extended to other units.
Key words: Steam turbine; Valve; Leak test
汽门严密性试验直接关系到机组的安全运行,包括主汽门严密性试验和调速汽门严密性试验两项[1-2]。除部分进口机组和--些小机组每年进行汽门严密性试验,还有近40%的机组不进行,特别是国产200MW机组。原试验标准要求转速超过 3000r/min的汽轮机开始做汽门严密性试验[3-5,而绝大部分机组的临界转速在1000~2000r/min,由于部分机组的轴系存在问题,在降转速过程中,过临界转速时振动大[6-7],导致试验无法进行。为此提出采用1000r/min以下转速进行严密性试验的方法,既不在临界转速区范围,又节省了试验时间。
1试验方法
1.1调速汽门严密性试验
机组解列后,打闸,待转速下降到1000r/min 后,重新挂闸,控制转速:进行调速汽门严密性试验,关闭调速汽门,如果DEH系统无汽门严密性试验功能,可采用OPC动作电磁阀关闭调速汽门(保持关闭状态,直到转速下降到规定的转速为止)。为保证中压主汽门和调速汽门前压力满足试万方数据
验要求,在试验过程中,应开启一级旁路以保证再热器压力,高、中压自动主汽门处于全开状态,每隔30s记录一次转速、主汽压力、主汽温度、高压调速级压力、高压排汽压力和温度、再热蒸汽压力、再热蒸汽温度、一级旁路后压力和温度、二级旁路后压力和温度、凝汽器真空和高、中、低压缸胀差,直到转速下降至合格转速为止。面后恢复机组转速至1000r/min。
在以往的试验中,往往只注意保持主汽压力,而忽略再热蒸汽压力,会使中压主汽门、调速汽门前压力不够,相当于没有进行中压汽门的严密性试验。因此,试验中应保持再热蒸汽压力在50%额定压力以上。
1.2主汽门严密性试验
机组转速恢复后,关闭高、中压自动主汽门,开大高、中压调速汽门,每隔30s记录一次转速、主汽压力、主汽温度、高压调速级压力、高压排汽压力和温度、再热蒸汽压力、再热蒸汽温度、一级旁路后压力和温度、二级旁路后压力和温度、凝汽器真空和高、中、低压缸胀差,直到转速降至合格转速为止。而后恢复机组转速至1000r/min。