JJF(冀)195-2021
小型蒸汽灭菌器温度、压力参数校准规范
Calibration Specification for Temperature and PressureParameters of Small Stream Sterilizer
2021-12-01 实施
2021-09-16发布
目录
引言....................................................................................................................................... (1)
1 范围................................................................................................................................... (1)
2引用文件........................................................................................................................... (1)
3 术语................................................................................................................................... (1)
3.1 灭菌温度....................................................................................................................... (1)
3.2灭菌保持时间............................................................................................................... (1)
3.3 灭菌温度带................................................................................................................... (1)
3.4温度偏差....................................................................................................................... (1)
3.5 温度均匀度................................................................................................................... (1)
3.6温度波动度................................................................................................................... (2)
3.7 压力示值误差............................................................................................................... (2)
4概述................................................................................................................................... (2)
5 计量特性........................................................................................................................... (2)
6 校准条件........................................................................................................................... (3)
6.1 环境条件....................................................................................................................... (3)
6.2负载条件....................................................................................................................... (3)
6.3 校准用设备................................................................................................................... (3)
7 校准项目和校准方法....................................................................................................... (4)
7.1 校准项目....................................................................................................................... (4)
7.2 校准方法....................................................................................................................... (4)
7.3 数据处理....................................................................................................................... (5)
8校准结果的表达............................................................................................................... (7)
9复校时间间隔................................................................................................................... (8)
附录 A原始记录格式示例.................................................................................................. (9)
附录 B校准证书内页格式示例........................................................................................ (10)
附录 C小型蒸汽灭菌器温度上偏差测量结果的不确定度评定示例............................ (11)
附录 D小型蒸汽灭菌器压力示值误差测量结果的不确定度评定示例........................ (14)