试验研究】
www.batterychn.com
浮充电压对阀控式铅酸蓄电池寿命的影响
胡杰",吴喜攀2,陈文艺
(1.泉州市圣能电源科技有限公司,福建泉州362442; 2.沈阳君威新能科技有限公司,辽宁沈阳110036)
摘要:通过对阅控式铅酸蓄电池浮充使用寿命失效原因的分析,发现浮充电压过低会造成蓄电池硫酸盐化的积累,使活性物质不可逆,最终导致蓄电池失效。过低的浮充电压也是造成蓄电池使用寿命缩短的原因之一
关键词:阀控式铅酸蓄电池;浮充电压;寿命;硫酸盐化
中图分类号:TM912.4
文献标识码:B
文章编号:1006-0847(2011)01-31-05
Theeffectof floatvoltageontheservicelifeofVRLAbatteries
HU Jie',WUXipan',CHENWen-yi
(l.QuanzhouSt.canPowerTechnologyCo.,Ltd.,QuanzhouFujian362442
2.Shenyang Junwei New Energy Technoloy Co., Ltd, Shenyang Liaoning I10036, China
Abstract: Through the analysis of the failure of VRLA battery due to float service life, we found that the overly low float voltage will cause the accumulation of reversible lead sulphate, leading to failure of battery. It is considered that the excessive low float voltage is one of the reasons for shorting the service life of leadacid battery
Key words: valveregulated leadacid battery; float voltage; life; sulphation
1前言
在目前应急电源(EPS)和不间断电源(UPS)的应用领域,主要是用固定型阀控式铅酸著电池(以下简称蓄电池)作为储备能源。一且遇上某些突发事件或自然灾害,市电停止,一些消防设施、事故照明、应急照明、电脑外设等就靠这些EPS或 UPS提供持续、稳定、不间断的电力,供应其重要的设备。另外,随着社会的信息化,EPS和UPS 亦广泛地应用于信息采集、传送、处理、储存的各
收稿日期:2010-08-10 万方数据
个环节,其重要性日益显现。
EPS和UPS在系统设备中,主要用途还是应急和备用,蓄电池作为能源,在其整个寿命期间要保证一定的储备容量,这样就要求对蓄电池进行长期的浮充电,可谓“养兵千日,用兵一时”。但在工作实践中,往往一些EPS和UPS用蓄电池的使用年限短,寿命不到一、二年基至更短,蓄电池达不到系统设备要求的延时时间,给用户带来了损
失,也增加了电池制造厂售后服务的压力。 2故障现象
某证券公司营业部电脑主机房配置了240V
201iNa.iVoL4831