12
doi:10.3969/j. issn.1009 3230.2017.08.004
应用能源技术
2017年第8期(总第236期)
汽轮机安全油泄漏及临时处理措施的思考
孙佳
(江苏太仓港协鑫电厂,江苏太仓215433)
摘要:文中介绍江苏太仓港协鑫电厂最近由于汽轮机安全油泄漏引起的两起事故情况,探讨了通过临时固定汽轮机隔膜阀,在不用长时间停机的情况下,保证汽轮机正常工作,等待申请临时停机检修处理。汽机手动“打闸”功能失去时,必须做好事故预案,保证AST电磁阔动作正常,防止汽轮机跳闸时事故扩大。
关键词:汽轮机隔膜阀;ETS保护;AST电磁阀
中图分类号:TK471
文献标志码:B文章编号:1009-3230(2017)08-0012-03
Consideration of Turbine Safety Oil Leakage andTemporaryMeasures
SUNJia
(JiangsuTaicangPortXiexinPowerPlant,Suzhou215433,JiangsuProvince,China)
Abstract: This article introduced two accidents from Jiangsu port of Taicang power plant recently due to leakage of turbine safety oil,discussed the temporary fixed steam turbine diaphragm valve,without long time down to ensure the normal work of the steam turbine, waiting to apply for temporary downtime treatment. When the turbine's Manual "turm ofr" function lost,the accident plan must be prepared to ensure the normal operation of the AST electromagnetic valve and prevent the accident from expanding when the turbine tripped.
Key words:Steam turbine diaphragm valve; ETS protection; AST solenoid valve
0引言
太仓港协鑫电厂最近发生两起由于调速系统漏油引起的两起不安全事件,由汽轮机安全油压泄漏引起汽轮机隔膜阀上部安全油压下降导致。安全油压降低时,为了防止隔膜阀泄掉EH油压引起ETS动作,可临时把隔膜阀固定在关闭位置,这样即使安全油压降低也不会引发ETS动作。此时必须保证AST电磁阀能够按要求动作,否则汽轮机保护无法动作,将导致事故不可控。 13号汽轮机隔膜阀漏油,临时处理 1.1事件经过
2016年6月14日,运行人员发现3号机主
收稿日期:201706-18
修订日期:201707-10
作者简介:孙佳(1981-),男,工程师,本科,主要从事电
力企业运行、技术管理工作。
万方数据
机隔膜阀上部漏油,检修人员进行螺栓紧固后,上部漏油消失,但是从隔膜阀下部腔室检查孔有油漏出。在主机隔膜阀中部阀杆位置安装临时限位器,防止因膜片漏油造成油压降低,隔膜阀误动,导致汽轮机ETS动作。
2016年7月5日发现漏油情况严重,已出现喷油现象。立即进行隔膜阀在线更换,为了泄去 3号机组隔膜阀上部油压,必须将机械脱扣手柄置于脱扣位置。当机械脱扣手柄打至脱扣位置时,隔膜阀上部无油漏出,检修人员进行隔膜阀更换操作。更换完毕后,漏油现象消失,安全油压恢复正常值。
1.2原因分析
太仓港协鑫电厂3号机汽轮机选用的是美国 FISHER公司生产的655D-42型隔膜阀,该隔膜