· 80·
第32卷第2期 2011年2月
电力建设
Electric PowerConstruction
中图分类号:TK267文献标志码:B文章编号:1000-7229(2011)02-0080-04
VoL.32, No.2 Feb,2011
660MW超临界直接空冷汽轮机整套启动中的
问题及处理措施
唐广通,南伟亮,李晖,张伟江,李泽敏
(河北省电力研究院,石家庄市,050021)
Treatment andProblemsEncountered inUnit Start-up of the660MW
Supercritical Direct Air Cooling Turbine
TANG Guangtong,NAN Weiliang,LI Hui,ZHANG Weijiang,LI Zemin
(Hebei Electric Power Research Institute,Shijiazhuang 050021, China)
ABSTRACT: This paper analyzes the problems encountered in unit start-up of the 660 MW supercritical direct air cooling turbines and proposes measures to address them; summarizes the operating characteristics of this type of units, which can be used as a reference for start-up and commissioning of similar types of units.
KEYWORDS: supercritical; direct air cooling; turbine; unit start-up;commissioning:660 MW unit
摘要:对660MW超临界直接空冷汽轮机在整套启动中遇到的问题进行研究分析,并采取措施予以解决:对该类型机组的运行特点进行了总结,供同类型机组的启动调试参考。
关键调:超临界:直接空冷;汽轮机:整套启动:调试:660MW 机组
doi: 10.3969/j.issn.1000-7229.2011.02.019 0引言
国华定洲发电有限公司二期工程2x660MW汽轮机发电机组,汽轮机为哈尔滨汽轮机厂生产的 CLNZK660-24.2/566/566型超临界、一次中间再热、二缸二排汽、直接空冷凝汽式汽轮机,空冷岛为西北电力设计院设计、江苏双良集团供货。本文针对此类型汽轮机在整套启动调试中遇到的问题进行分析,并提出处理方法。
1冷态启动参数优化 1.1冷态启动存在的问题
根据哈尔滨汽轮机厂推荐的机组启动曲线,汽机冷态启动的冲转参数为:主蒸汽8.92MPa/360℃,再热蒸汽1.0MPa/320C。而现场的调试实践证明,直流锅炉难以满足这样的冲转参数。因为直流锅炉启
万方数据
动时有最小流量限制,吸收同样热量下,直流锅炉产生的蒸汽量要小于汽包炉。而超临界直流锅炉为了保证启动时水冷壁和过热器的冷却,需要较高的启动压力。若要将主蒸汽力提高到8.9MPa,就必须增加懿料量以增加产汽量,而加大了燃料量后,炉内的烟气流量增加,烟气温度增高,从而提升了蒸汽温度。在这样的蒸汽压力下,主、再热汽温在汽机冲转前就接近500℃,可能引起汽轮机胀差超限、应力过大等问题。
1.2解决方案
与汽轮机厂家、锅炉厂家共同协商后,兼顾锅炉和汽轮机启动要求,将冷态启动参数修改为主汽压力不低于5MPa,主汽温度380~410℃,再热蒸汽压力 0.4~1.0MPa,再热蒸汽温度不高于430℃。同时为了更好地控制汽温不超温,采取了提高辅汽压力以提高给水温度、降低锅炉最小流量(从30%BMCR降至21% BMCR,BMCR为锅炉最大连续蒸发量)等方法。实践证明采取上述措施能够保证机组冷态启动时各参数在规定范围内,从而保证了机组冷态启动的顺利进行。
机组冲车中转速飞升 2
2.1事件发生过程
机组采取高、中压联合启动方式首次冲车,转速 600r/min以下由中调门控制机组转速。机组升速至 200r/min左右时,中调门突然开展,机组转速也飞升
至600r/min以上,运行人员立即手动打闸。 2.2原因分析
通过转速历史曲线发现冲车至200r/min时,3个数字电液控制系统(digital electro-hydrauliccontrol system,DEH)转速有2个发生故障,存在较大的摆