2015年第36卷第1期
氮肥技术
板式空气预热器的实验研究
管淑豪
(中石化金陵分公司项目管理部江苏南京210033)
葛京鹅
章世斌
13
(南京圣诺热管有限公司江苏南京210009)(中国酒泉卫星发射中心甘肃酒泉732750)
摘要介绍通过实验准确测定板式空气预热器空气和烟气在各板面处的对流换热票数a和g,再通过务塞尔准数的
通用幂函数求得板式空气预热器的压力降损失△Pa和Pg.以便于进行板式空气预热器的优化设计关键词板式空气预热器实验对流换热系数阻力系数
Experimental research of plate-type air pre-heater GUAN Shuhao(Jinling Branch Sinopee, Nanjing 210033, Jiangsu Province) GE Jingpeng(Nanjing Shengnuo Reguan Co., Lid., Nanjing 210009, Jiangsu Provinee) ZHANG Shibin (China Jiuquan Satellite Launch Centre, Jiuquan 732750, Gansu Province)
Abstract The paper introduces convective heat transfer coefficient ha and hg of flue gas each panel and plate air preheate air are measured accurately through experiment, then obtained pressure drop los of plate air preheater Par and Pg by Nussel numher, which in order to optimize design of plate air preheate
Keywords platetype air preheater; experiment; eonvective heat transfer coefficient; resistance coefficienl
1前言
化肥工业炉(如吹风气余热回收系统的燃烧炉)烟气余热在工艺系统利用后,烟气温度一般在350℃以下,有的采用空气预热器回收利用低温烟气余热。空气预热器的发展从管壳式、热管式、相变锅炉等发展到采用ND钢到钢管表面的陶瓷复合,最近又发展了铸铁板翅式换热器叫。板式空气预热器是上世纪80年代末由国外引人项目时带入,后由国内石化工程公司进行了消化吸收并在其设计的项目中予以应用,取得了较好的效果,随即国内各制造企业开始了产业化应用。各个企业对干板式空气预执器设计准删的把据不尽相同,由此导致工程应用中出现了各种各样的问题日,如图1所示就是板式空气预热器设计面积过大而导致了露点腐蚀:该装置运行仅40d 就被迫停工。可见,不同结构板式空气预热器的性能与设计准则应该是有差异的,所以用实验确
定对应结构的板式空气预热器的设计准则是至关重要的(4,.5)
图1露点腐蚀图
板式空气预热器设计参数
本实验板式空气预热器,用空气吸收烟气的热量,提高烟气余热的利用效率,节约能源。实验的主要依据是热力学第一定律一一执平衡原理,即当系统达到平衡状态时,冷空气所吸收的热量等于烟气所放出的热量。化肥工业炉烟气余热利用中的空气预热器传热方程为: