36
doi:10.3969/j. issn. 1009 3230.2015.05.012
应用能源技术
2015年第5期(总第209期)
板式换热器换热片结垢判断方法研究
孙成,梁子元”,梁瑞玲
(1.河北华电石家庄裕华热电有限公司,石家庄050041; 2.石家庄华电供热集团有限公司,石家庄050000)
摘要:板式换热器以其优良的传热性能在石油、电力、化工等行业得到广泛应用。但污垢的存在会降低板式换热器的换热效率,增大压降,造成能源的浪费。文中总结前人经验,从多角度出发,判断板式换热器的结垢情况。
关键调:板式换热器;结垢;方法
中图分类号:TK224.2文献标志码:B文章编号:1009-3230(2015)05-0036-04 Researchonthemethod ofplateheatexchangerfoulingjudgment
SUN Cheng', LIANG Zi - yuan', LIANG Rui - ling
(1.Huadian Shijiazhuang Yuhua Thermal Power Co Ltd,Shijiazhuang 050041,China;
2.ShijiazhuangHuadianHeating GroupCo.Shijiazhuang050000,China)
Abstract: Plate heat ex - changer was widely used in the oil,electric power,chemical and other industry because of its good heat transfer performance . However,the existence of dirt will reduce the heat transfer efficiency, increase the pressure drop, as well as cause the waste of energy. To summarize, this text will analyze the scaling situation of the plate heat ex changer from multi angle with scholars valuable experiences.
Key words: Plate heat ex - changer; Fouling; methods
0引言
换热器是将热流体的部分热量传递给冷流体的设备,又称热交换器。换热器种类很多,根据冷、热流体热量交换的方式可分为间壁式、混合式和蓄热式换热器。在三类换热器中,间壁式换热器应用最多。板式换热器是典型的间壁式换热器。它是由一系列具有一定波纹形状的金属片叠装压紧而成的一种新型高效换热器。由于其具有换热效率高(其传热系数比管式换热器高3~5 倍)、占地面积小(为管式换热器的1/3)、板片形式多、组装灵活、拆卸清洗检修方便、结构紧淡等
收稿日期:2015-0325
5修订日期:2015-0411
作者简介:孙成(1974-),男,河北石家庄人,主要从事电厂
热力动能工作。
万方数据
优点,板式换热器在电力、石油、化工、食品、空调等各个行业有着极其广泛的应用1-2】。
板式换热器结垢的危害
1
对换热设备的投资约占化工行业总投资的 70%,炼油行业的35%~40%,火力发电厂的 40%以上(3]。但是,几乎所有的换热器运行一段时间之后,都会存在程度不等的结垢现象。
板式换热器发生结垢会带来如下一些危害(4-5] ;
(1)由于结垢会导致板式换热器的流通截面积缩小,阻力增大,增加了冷却水水泵的电耗;
(2)当板式换热器表面污垢的厚度达到一定程度后,会影响其换热效率,使传热系数减小,换热器性能下降,严重的会导致局部温度过高,甚至