第39卷,第2期 2010年3月
文章编号:1000-7466(2010)02-0006-06
石油化工
设
PETRO-CHEMICAL EQUIPMENT
往复式压缩机失效载荷分析陈峰,郭永平!,纪琳1,曹玉伟",苏志忠
(1.中国石油天然气股份有限公司独山子石化分公司,新疆独山子833600;
2.新疆大学机械学院,新疆乌鲁木齐830000)
Vol.39No.2 Mar.2010
摘要:根据DW-34.7/(11.5-53)-X型往复压缩机失效实例,通过有限元、冲击载荷材料力学等力学分析手段对该机组一级活塞、十字头等失效部件损坏的特征、部位及失效原因进行了分析研究,据此提出了相应的设计及运行措施。
关键词:往复式压缩机;高周疲劳;低周疲劳;冲击裁荷;应力集中;有限元法
中图分类号:TQ051.21
文献标志码:A
FailureLoadAnalysisofReciprocatingCompressor
CHEN Feng',GUOYong-ping',JI Lin',CAO Yu-wei',SUZhi-zhong
(1.Dushanzi Petrochemical Company of China National Petroleum Corporation,Dushanzi 833600
China;2.School of Machinery Engineering, Xinjiang University, Urumqi 830000, China)
Abstract: By DW-34.7/(11. 5-53) -X-type reciprocating compressor failure example, using stat ic finite element analysis, mechanics of materials analysis of the impact load, such as mechanical analysis means. Analysis of the piston, crosshead and other damaged components, such as failure characteristics, location and reasons for failure. According to analysis, recommendations have beenmade.
Key words: reciprocating compressor; high cycle fatigue; low cycle fatigue; impact load;
stress concentration; finite element method
某公司乙烯厂甲醇装置C102B新鲜气压缩机为固定水冷对称平衡两列两级无油润滑型往复活塞式压缩机。其型号为DW-34.7/(11.5-53)-X,压缩介质为新鲜气(氢气、一氧化碳)。其电机功率为 900kW,轴功率845kW,转速333r/min。一级活塞行程280mm,一级人口压力1.15MPa,一级出口压力2.75MPa,一级最大活塞力3.14×10§N,一级人口温度40℃,一级出口温度125℃;二级人口压力2.75MPa,二级出口压力5.3MPa,体积流量(标准状态)12232m/h,实际体积流量(标准状态)7400m/h。联锁保护条件为:润滑油压力低于0.12MPa时停运,润滑油温度低于15℃C时不能启动。
收稿日期:2009-11-09
该机组2004年投人运行,2009-02-22,压缩机活塞、十字头发生失效事故。一级十字头颈部断裂,级活塞轴侧部位破裂(图1),盖侧完好,活塞轮毂
图1级活塞轴侧端面
作者简介:陈峰(1970-),男,江苏邵州人,高级工程师,颈士,主要从事设备失效分析、状态监测及管理工作。