2016-07
技术应用与研究
当代化工研究35 henn
堵塞式压力计验封资料分析与应用
O鲁琳王雪娇
(中国石油冀东油田公司开发技术公司河北063200)
摘要:整对是检验分层注求并层段密状况的重要手段,其结果的好坏直接影响了分层注水质量。目前,赌害式压力计作为检证对隔器
情况的有效方法之一,得到广泛应用,本文就嘴塞式压力计的验对方法,测试资料分析方法及其应用进行了分析阐述。关键词:验对;塞式压力计
中图分类号:T
文献标识码:A
Plugtypepressuregaugetestdataanalysisandapplication
Lu Lin, Wang Xuejiac
(China petroleum jidong oilfield company technology development company, Hebei, 063200)
Abstracf: check seal is testing layered water injection well interval important means of sealing condition, the result is good or bad directly affects the qaality of rhe layered water injection.Ar presen, zhe plegging type pssure gaage as test packer is one of effective methods, has been widely tesed.In this paper, the fest of plugging type pressare gaage sealing merhod, tesr data analysis method and its application are analyzed in this paper
Key words: check seal; Block oype pressure gange
前言
随着油田开采的持续推进,地层压力不断下降,分层注
水成为保持油层压力、补充地层能量的有效手段。通过实施有效的分层注水可提高水驱控制程度及水驱动用程度,提高最终采收率,而验封作为检验分层注水并层段密封状况的重要手段,直接影响了分层注水质量。
目前,堵塞式压力计在油田广泛应用,其验封效果较
好。堵塞式压力计可利用分层段测试地层压力、温度参数,绘制出压力、温度、时间坐标曲线图,根据测得的数据曲线来判断封隔器密封情况。同时,针对判断验封合格并的分
析,还可从曲线中初步获得各层段地层压力。一、偏心分注并验封方法(堵塞式压力计)
在偏心配水器中投入堵塞式压力计后自下而上逐级验封。
以三级四段(作业并)为例
1.在地面将偏!、偏IV配水器中装入堵塞器,偏Ⅱ、偏配水器中装入堵塞式压力计:
2.封隔器座封后,开始进行验封测试,首先捞出偏IV配水器中的堵塞器,打压验证第三级封隔器密封状况
3.捞出偏配水器中的堵塞式压力计,打压验证第二级封隔器密封状况:
4.捞出偏Ⅱ配水器中的堵塞式压力计,打压验证第一级封隔器密封状况;
5.捞出偏1配水器中的堵塞器。
对于作业井直接进行地面打压操作进行验封,对于正常注水井,可采取反复调节地面油压“升-降-升”的操作方式进行验封。
二、验封资料分析方法
1.常压地层
对于常压注水层的验封资料,通过回放堵塞式压力计现场实测压力数据,观察验封段打压过程的压力变化,判断压方方数据
差在2MPa范围内的验封结果为合格。
G62-26井为两级两段分层注水井,该井于2014年6月
6日进行作业验封。2014年6月3日在地面将偏Ⅱ配水器中装入堵塞器,偏1配水器中装入堵塞式压力计。6月6日封隔器座封(打压座封)后,开始进行验封测试。
首先捞出偏ⅡI配水器中的堵塞器,打压10MPa,验
证第二级封隔器座封状况。下图为偏!压力计实测曲线图,A-B为压力计下并过程,C-D为打压验封过程,实测压力从28.218MPa上升到29.213MPa,最大上升0.995MPa,如图2所示,判断第二级封隔器座封合格。
L
图1偏I压力计实测曲线图(G62-26)
图2压力曲线验封过程放大曲线图(G62-26)
捞出偏1配水器中的堵塞式压力计,地面打压验封,验