2011年第2期(总第158期)
应用能源技术
内展翅片换热器应用在压缩空气系统中
的节能效益分析钱北中,李强,刘树风
(哈药集团制药总厂,黑龙江哈尔滨150086)
摘要:文中通过实验数据分析以及实际工程案例,就内展翅片换热器在压缩空气系统的相同工况下,采用光管换热器和外翅片换热器的换热效果及阻力特性进行了比较,结果表明,内展翅片换热器不仅具有较好的强化传热效果,而且单位压降损耗低,节能效采显著。
关键词:内展翅片换热器;强化传热;压降;节能
中图分类号:TV831.3
文献标志码:B
文章编号:1009-3230(2011)02003303
Energy-saving Benefit Analysis of Internal Finned Heat
Exchangers Applied in Compressed Air
QIAN Bei-zhong LI Qiang LIU Shu-feng
(General Pharmaceutical Factory of Harbin Pharmaceutical Group, Harbin 150086, China) Abstract : Through the analysis of experimental data and practical project cases, the article compares the heat exchange efficiency and resistance characteristic of intemally finned tube heat exchanger, smooth-tube heat exchangers and extermally finned tube heat exchanger under the same working condition of compressed air. It turms out that intermally finned tube heat exchanger not only has better auaeeoddaaosenaoeoasenaaoe saving effect.
Key words: Intermally finned tube heat exchanger; Heat transfer enhancement; Pressure drop; En-ergy conservation.
0前言
哈药集团制药总厂压缩空气系统中空气压缩机后端的空气冷却装置原使用的是外翅片空气冷却器,设备运行阻力较大,造成整体工艺系统的动力不足,只能通过增大空气压头的方式来调节,增大了能源消耗量。2009年底在工艺系统改造中接触到了内展翅片换热器,了解到该换热器具有传热效率高、压力降小、节能节水等优点,于是该广在此饮系统改造中使用内展数片换热器替换原有外翅片换热器。为了明确使用内展翅片换热器后所带来的经济效益,对内展翅片换热器的性能进行了分析,并就原有外翅片空气冷却器运行参数进行了对比。
收稿日期:2010-12-15
修订日期:20101227
作者简介:钱北中(1954-),男,高级工程师,主要从事工厂
能源动力系统管理。
万方数据
1内展翅片换热器实验数据分析 1.1实验系统
33
根据内展翅片换热器厂商提供的西安交通大学动力工程多相流国家重点工程实验室“关于内展翅片对流及冷凝相变传热及阻力性能研究”的报告内容,实验系统简述如下:空气单相对流传热实验系统由两部分组成,如图1所示。第1部分为空气回路,由空气压缩机、孔板流量计、单管电加热段、管束(套管)试验段、空气冷却器、转子流量计组成。试验工质空气由空气压缩机压至试验系统内,由旁路调节所需要的空气流量,进人单管电加热段按两点式加热方式由纯铜极板加热后进入管束(套管)试验段,试验后的空气经冷却后排至大气,整个系统的压力由系统最末端的背压阀门控制。该系统采用了孔板与转子流量计两个空气流量测量装置,试验中的测量结果以孔板流量