2013年第6期(总第186期)
doi:10.3969/j. issn. 1009 3230.2013.06.010
应用能源技术
33
某300MW机组回转式空气预热器性能试验及改造方案
何勇超
(河北华电石家庄裕华热电有限公司,石家庄051430)
摘要:回转式空气预热器是大型电站锅炉广泛采用的尾部换热设备,其性能对锅炉效率有很大影响。文中依据某300MW机组回转式空气预热器的漏风、换热效率、烟气侧阻力及出口烟温试验结果,分析其运行中所存在的问题,提出相应的改造方案,并对该方象进行运行经济性和可靠性评估。
关键词:回转式;空气预热器;试验;改造方策
中图分类号:TK229.5
文献标志码:B
文章编号:10093230(2013)060033-03
A3ooMWUnitofRotaryAirPreheaterPerformanceTesting
andTransformation
HEYong-chao
(Hebei Huadian Shijiazhuang Yuhua Cogeneration Co.,Ltd, Shijiazhuang 051430,China) Abstract: Rotary air preheater is the rear heat exchanger equipment of a large power station boiler. It has a great impact on the performance of the boiler efficiency. According to the test results of air leakage, heat transfer efficiency, resistance and temperature of the gas export side, the problems in its operation is analyzed and the transformation program which is based on economy and reliability assessment is put forward.
Keywords:Rotary; Air preheater; Test;Transformation program
回转式空气预热器是目前国内大中型火电厂广泛采用的锅炉辅助设备,其性能优劣对锅炉效率有很大影响。因此,提高回转式空气预热器性能对火电厂节能降耗、提高整个机组效率具有重大意义(1-4)。文中依据某300MW机组回转式空气预热器的漏风、换热效率、烟气侧阻力及出口烟温的试验结果,分析了其运行中所存在的间题,提出了相应的改造方案,并对该方案进行了运行
经济性和可靠性评估。 1试验结果分析
1.1空气预热器漏风试验
0 收稿日期:20130311
修订日期:201303-28
作者离介:何勇超(1977-),男,副总工程师,主要从事电厂
运行检修技术管理工作。
万方数据
进行了回转式空气预热器漏风试验,结果见表1。
表1 项目漏风率设计值
300 MW
A例 9.4 5
B例侧 11.4 5
满风审试验
270 MW
A侧
B例
10.7412.29
5
5
240 MW
A侧 13.42 5
B例 14.07 5
由表1可知,在上述三个负荷下,空气预热器漏风率均大于10%,且B侧漏风高于A侧。造成这一现象的原因,主要是由于该机组长期燃用非设计煤种,煤质分析见表2,实际运行中总的烟气量和飞灰量大大超过设计值,加速了空气预热器内部换热元件的磨损,且由于B侧烟气挡板开度大于A侧,造成B侧烟气流量偏大,增加了B侧的磨损程度,故其漏风率也较大。