您当前的位置:首页>论文资料>ICP-OES法测定铅锭中微量杂质元素

ICP-OES法测定铅锭中微量杂质元素

资料类别:论文资料

文档格式:PDF电子版

文件大小:147.68 KB

资料语言:中文

更新时间:2025-01-15 11:42:58



推荐标签:

内容简介

ICP-OES法测定铅锭中微量杂质元素 www.batterychn.com
ICP-OES法测定铅锭中微量杂质元素
杨秀艳,韩艳萍
(扬州阿波罗蕃电池有限公司,江苏扬州225131)
摘要:研究了ICP-OES(电感病合等离子体发射光谱仪)法测定电解铝中杂质Ag、Cu、Bi、 As、Zn、Fe、Cd、Ni的含量,本文进行了实际样品的精密度、准确度试验,结果表明本方法快速、准确,实用,可以满足铅键中杂质含量的分析要求,RSD<1%,回收率95%~102%。关键词:ICP-OES;铅锭;微量杂质元素
中图分类号:TM912.1
文献标识码:B
文章编号:1006-0847(2013)03-137-03
DeterminationoftraceimpurityelementsinleadbyICP-OEs
YANG Xiu-yan,HAN Yan-ping
(YangzhouApolloBatteryCo.,Lid.,YangzhouJiangsu22513I,China)
Abstract: An ICP-OES method for the determination of trace impurity elements of Ag, Cu, Bi, As, Zn, Fe, Cd and Ni in lead had been developed in this paper. The method were verified with actual samples on accuracy and precision. The results showed that the method was quick and easy to operate. It was
met the requirement of analysis. The recoveries could reach 95 %~102 % with RSD<1 % Key words: ICP-OES; lead pig; trace impurity element
0前言
铅是铅酸蓄电池生产过程中所用的主要原材料之一,铅中杂质含量的高低直接影响电池的性能,杂质含量高时,电池的自放电增加,水损失增加,电池容量下降,使用寿命短。所以检测铅中的杂质是非常重要的。
一般按《GB/T4103铅及铅合金化学分析方法》测试制造蓄电池用铅粉所用的铅锭,其中有化学分析法、分光光度法、原子吸收法等,这些方法使用药品多,操作繁琐,分析时间较长。本文使用
收稿日期:2012-10-10 万方数据
电感耦合等离子发射光谱法(ICP-OES)测定铅锭中的杂质元素含量,方法简单、快速、准确,结果
令人满意。 1实验部分
1.1主要仪器和试剂
ICP-OES2100(美国PE公司生产),所用氩气纯度为99.996%以上,氮气纯度在99.996%以上:所用试剂均为优级纯;所用水皆为电阻率大于5×1052*cm的高纯水,玻璃仪器使用前用硝酸(1+1)浸泡24h,之后用自来水冲洗,再用高纯
水冲洗干净使用。 1.2仪器工作参数
ICP-OES光谱仪工作条件:频率40.68MHz;功率1.300kW;等离子体冷却气流量15L/min,辅
13
上一章:活性炭的制备及其在铅酸电池中的应用 下一章:KMC高离能电解液的研究与应用

相关文章

SN/T 3363-2012 铅锭中杂质元素含量的测定电感耦合等离子体原子发射光谱法 ICP-MS 法测定食品级壳聚糖中的微量杂质元素 GB/T 30902-2014 无机化工产品 杂质元素的测定 电感耦合等离子体发射光谱法(ICP-OES) EJ/T 20170-2018 金属铀中20种微量杂质元素的测定 电感耦合等离子体原子发射光谱法 ICP-OES法测定穿心莲药材中6种重金属元素溶出特性的研究 微波消解-原子吸收光谱法测定山西老陈醋中微量元素 电感耦合等离子体质谱法测定锰酸锂中杂质元素 原子吸收光谱法测定新疆不同居群大蒜中微量元素的含量