4
doi:10.3969/j. issn.1009 3230.2015.07.002
应用能源技术
2015年第7期(总第211期)
核电站部分容量轴加及其旁路选型研究
郑钢,赵丹阳
(国核电力规划设计研究院,北京100095)
摘要:核电站部分容量轴加的容量及其旁路节流孔板的选型需通过计算来确定,通过计算可以发现设备厂家提供的轴加容量是否满足系统运行要求,要确保凝结水最小流量再循环流量不至于过大,并可以根据文中提供的方法选出合适的节流孔板孔径,计算出凝结水最小流量再循环流量。
关键词:轴封加热器,节流孔板,凝结水最小流量再循环中图分类号:TL27
7文献标志码:B文章编号:1009-3230(2015)07-0004-04
Study onPart CapacityGland SteamHeaterandits Bypass
UsedforNuclear-fueledPlants
ZHENG Gang,ZHAO Dan-yang
(State Nuclear Electric Power Planning Design & Research Institute,Beijing 100095,China) Abstract: Capacity of part capacity gland steam heater and throttle orifice in its bypass need to be confirmed by actuation, we will find that if the capacity which is supplied by manufactory can be satisfied to system operation.We must confirm that condensate recirculation is not too large. Also size
of throttle orifice and flow of condensate recirculation can be got by methods in this article. Key words: Gland steam heater; Throttle orifice; Condensate recirculation
0引言
轴封加热器(以下简称轴加)是汽轮机轴封和门杆蒸汽系统的重要设备,为了维持汽轮机的轴封漏汽能够在轴加中冷却凝结,不至于蒸汽从汽轮机轴端漏到厂房和汽轮机润滑油系统,无论后动停机、低负荷还是正常运行,都必须保证有定量的凝结水冷却轴加。同时为了保证凝泵不汽蚀,凝泵也必须保证任何时候不能低于其允许的最小流量。影结水的最小流量再循环流量取意泵组和轴加最小流量(如果轴加为部分容量,则取凝结水主管路上的流量)的较大值。
核电站主蒸汽为饱和蒸汽,蒸汽参数低,凝结收稿日期:2015-0620
)修订日期:2015-0629
作者简介:郑钢(1981-),男,热能与动力工程专业,工程
师,主要从事AP1000压水堆核电站常规岛、大型火电机组机务专业的设计工作。
万方数据
水量很大,为了降低轴加成本和轴加制造难度,轴加往往采用了与火电全容量不同的部分容量,轴加设有带节流孔板的旁路。(如图1所示)如果轴加容量选型偏小,将导致凝结水系统最小流量再循环流量过大,甚至导致系统无法正常运行:如果孔板选型不当,凝结水量将不满足设计要求,有时还容易发生管路振动。文中将结合某核电工程实际,探讨--下部分容量轴加容量及其旁路节流孔板的选型。
1计算目标及思路
计算目标及思路如图1所示。 1.1计算目标
(1)判断厂家提供的轴加容量是否满足系统运行要求。
(2)如果计算判定厂家提供的轴加容量偏