44
doi :10. 3969/j. issn. 1009 3230. 2016. 08. 013
应用能源技术
2016年第8期(总第224期)
变电站直流电源典型缺陷风险评估及预控措施研究
鄂士平,宋兵,刘国兴
(国网湖北省电力公司检修公司,武汉430050)
摘要:在电力系统中,直流电源能否可靠运行是变电站安全运行至关重要的保证。文中分别介绍了变电站直流电源中充电整流模块、铅酸蓄电池组、直流微机监控装置、绝缘监察装置、电池巡检装置及直流断路器的工作原理、使用时注意事项、优缺点等,并针对不同部分的风险评估、预控措施、系统设备状态评价进行详细的阐述。
关键词:直流电源;监控装置;断路器;预控措施
中图分类号:TM63.4文献标志码:B文章编号:1009-3230(2016)08-0044-03 ypicalDefectsofDCPower Supplyin SubstationStudyontheRisk
AssessmentandPreventiveMeasures
E Shi ping, SONG Bing, LIU Guo xing
(State Grid Hubei electric Power Company Maintenance Company,Wuhan 430050,China) Abstract: In the electric power system, dc power supply can reliable operation is the assurance of substation is very important to safe operation. This paper introduces the charging in the substation dc power supply, lead - acid batteries, dc rectifier module of microcomputer monitoring device, insulation monitoring device, battery inspection device and the working principle of the dc circuit breaker, matters needing attention when using, such as the advantages and disadvantages, and in view of the different parts of the risk assessment, control counter measures and system equipment state evaluation in detail in this paper.
Key words: dc power; Monitoring device; Circuit breaker; Control counter measures
0引言
在电力系统中,直流电源稳定运行对变电站的安全运行起着至关重要的作用,同时也是电网安全运行的保障。在电力系统运行中,因直流电源设计不合理、设备选型不恰当、运行维护不规范而导致的电力设备损坏、系统故障、事故范围扩大、甚至造成人身伤亡事故时有发生,或者当变电站直流电源出现故障时,相关的运行检修人员不能及时有效地排除故障,甚至扩大事故范围、降低
收稿日期:2016-06-10
修订日期:2016-0720
作者简介:鄂士平(1979-),男,湖北当阳,高级工程师,从
事电网运维检修管理工作。
万方数据
供电可靠性,给供电系统及国家财产造成非常巨大的损失。因此对变电站直流电源做好缺陷风险评估及相应预控措施是必须优先解决的问题。变电站直流电源由充电整流模块、铅酸蓄电池组、直流微机监控装置、绝缘监察装置、电池巡检装置及直流断路器等部件组成,针对不同部件分别介绍
相应的风险评估及预控措施。 1直流电源的组成
变电站直流电源由充电整流模块、铅酸蓄电池组、微机监控装置、绝缘监察装置、电池巡检装置及直流断路器等部件组成。