2012年6月
化肥工业
分光光度法快速测定复合肥中有效磷含量的测量不确定度评定
张辰",席武军”
33
(1.营口市产品质量监督检验所辽宁营口115000;2.营口市第二工学校辽宁营口115000)
摘要分析了分光光度法快速测定复合肥中有效磷合量的测量不确定度的主要来源,对各不确定度分量进行了评定,求得合成标准不确定度和扩展不确定度分别为0.21%和D.42%。不确定度分析与评定结果表明:影响分光光度法快速测定复合肥中有效磷含量的测量不确定度的主要因素是标准工作曲线报合引入的不确定度,加强这方面的按制可提高测量结果的准确性。
关键词分光光度法有效磷不确定度评定
AssessmentofUncertaintyinRapidDeterminationofAvailablePhosphate
Content in Compound Fertilizers by Spectrophotography
Zhang Chen', Xi Wujun?
(1. Yingkou Product Quality Supervision and Inspection InstituteLiaoning Yingkou 115000 :
2. Yingkou Second Technical School Liaoning Yingkou 115000)
AbstractThe main sources of uncertainty are analyzed in rapid determination of available phosphate content in compound fertilizers by spectrophotlography, an assessment is made of various uncerlainty components, and it is found that thc composition standard uncertainty and extension uncertainty are respectively 0. 21% and 0. 42%. The results of uncertainty analysis and assessment show that the main factor affecting uncertainty in determination is the uncertainty introduecd into the standard working cure fitting, so strengthening the control in this respect will improve the precision of the determination results.
Keywords spectrophotography available phosphateuncertainty assessment
测量不确定度是评价检测结果可信性、可比性和可接受性的重要指标。根据JF1059-1999(1-的规定,对分光光度法测定复合肥中有效磷含量的测量结果不确定度的各个因素进行了分析和评定,以提高分析结果的准确性。
测量方法
1.1主要仪器与试剂
紫外光概分光光度计:752型,上海第三分析仪器厂。
本文作者的联系方式:5337zhangchen@163.com 万方数据
分析天平:AEU-210型,日本岛津公司。
恒温水浴振荡器:SHA-B型,富华仪器有限公司。
偏钒酸铵、钼酸铵、乙二胺四乙酸二钠(EDTA)和硝酸:均为分析纯。
磷酸二氢钾:基准试剂,质量分数≥99.95%,光复科技发展有限公司。
1mg/mL磷标准溶液(1mL溶液中含P,0, 1mg):准确称取1.9175g于105℃下干燥2h 的磷酸二氢钾,用适量的水溶解,溶解后移人