第41卷第8期 2013年8月
聚氯乙烯
Polyvinyl Chloride
Vol.41, No.8 Aug.,2013
氣化聚乙烯傅里叶变换红外光谱分析方法的改进
韩风”,杨雷,张坤明,董军宁,屈文召
(潍坊亚星化学股份有限公司,山东潍坊261031)
关键词氯化聚乙烯;红外光谱制样方法结构分析
摘要用傅里叶变换红外光谱仪分析氯化聚乙烯的结构,考察制样方法及样品膜厚度对测试结果的影响结果表明:用热压膜制样方法所得试样的红外谱图清晰、准确,信息全面;样品膜厚对测试结果会产生影响,厚度为 0.015~0.05mm时,所得红外谱图清晰,一致性好。
[中图分类号]TQ325.12;TQ014[文献标志码]B
[文章编号]1009—7937(2013)08—0036—05
Improvements on methods of analyzing the structure of chloroinatedpolyethylene
by Fourier transform infrared spectrometer
HANFeng,YANGLei,YANGKunming,DONGJunning,QUWenzhao
(WeifangYaxingChemical Co.Ltd.,Weifang261031,China)
Key words : chlorinated polyethylene ; infrared spectrum ; sample preparation method ; structur
alanalysis
Abstract : The structure of chloroinated polyethylene was analyzed by using Fourier transform infrared spectrometer , and effects of sample preparation methods and sample thickness on determi-nation results were investigated . The results showed that the infrared spectra of samples obtained by hot press were clear , accurate and informative ; the thickness of sample could influence the determi, nation results , and infrared spectra with high definition and good consistency could be obtained when the thickness was between 0 .015 and 0 .05 mm .
红外光谱属于分子光谱,它作为“分子的指纹” 广泛用于分子结构和物质化学组成的研究。测试原理为:当红外光谱照射到试样上时,试样中分子振动吸收特定波长的红外光而形成了有序的红外谱带,根据谱带频率、强度和形状可以判定试样的结构和组成。
在红外光谱的测试中,制样技术对测试结果会产生很大影响,同一个样品,采用不同的制样技术,可能会得到不同的光谱图,这在红外光谱的测试中经常遇到。因此,在具体的测试过程中,要根据样品的特性和要求,采用合适的制样方法
氯化聚乙烯是一种性能优异的高分子材料,广泛用于橡胶、塑料和其他特种制品中,它又是一种弹
*[收稿日期]2013—07—04
性体材料。为了能准确获得氯化聚乙烯产品信息笔者采用不同的方法制样,测试其红外光谱,比较不同方法的差异,从而确定氯化聚乙烯结构的最优测试方法。
1试验部分 1.1原料
氯化聚乙烯,潍坊亚星化学股份有限公司;其他
样品,市售。 1.2仪器
傅里叶变换红外光谱仪,ThermoNicoletIS10,测试范围400~4000cm-,分辨率4,扫描次数
[作者简介]韩风(1965一),女,高级工程师,1989年毕业于山东工业大学化工系,现主要从事氯化聚乙烯产品开发和
应用研究工作。 36