燃气技术GasTechnolegy doi:10.3969/j.issn.16715152.2011.01.006
国内外防腐检测前沿技术综述
北京永逸舒克防腐蚀技术有限公司(100029)韩汉清佟大为李建平高磊
摘要:本文以皮尔进检测法(PS)、交流电流衰减法(PCM)为切入点,对目前国内防离层检测的前沿
技术,进行了分析、研究,对3种国内外最新的地下管道防离层检测技术:直流电位梯度检测法(DCVG)、CIPS与DCVG联合检测方法、杂散电流测绘仪一SCM进行了介绍,并对未来地下管道防离层检测技术的发展方向进行了展望。
关键词:埋地管道防腐层检测技术
DomesticandForeignForefront Technologyof DetectiononCoatings Beijing YONGYISHUKE Anti-corrsion Technology CO.LTD Han Hanqing Tong Dawei Li Jianping Gao Lei
Abstract:In this paper, P/S detection and PCM detection are regarded as the point of contact, the forefront technology
of detection on coatings has been studied, and three kinds of domestic and foreign newest underground anticorrosive coatings detection including DCVG detection, CIPS & DCVG detection, SCM detection are been introduced. Based on these, the outlook of development of underground corrosion detection technology is put forward.
Keywords:Buried pipeline 1引信言
detection technology
coatings
目前,国内外地下管道防魔层检测方法有:管/地电位检测技术、皮尔逊检测法(PS)、交流电流衰
随着城市燃气的发展,用于天然气运输的地下金属管道越来越多。经过多年的运行,这些管道的防腐层会出现老化、剥离或破损等情况,使管体产生严重的腐蚀,造成管道漏气事故的发生,给燃气管道带来巨大的经济损失和安全隐惠。为此防腐层的定期检测,是对安全隐患防范意识由被动变主动的一种科学的管理手段。我公司在对燃气管线定期检测过程中,通过对检测数据仔细分析,确定涂层破损点,对地打孔检测使用嗅敏仪检测漏点,从而减少了突发的漏气安全事故,做到了由被动到主动安全管理运行模式的转变。减少因防腐层损坏而带来的事故和损失。
241城市地气:月刊方方数据
减法(PCM)、管中电流一电位法、变频一选频法、直流电压梯度测试技术(DCVG)、密间款电位检测(CIPS)。其中皮尔逊检测法(PS)、交流电流衰减
法(PCM)是目前常用检测方法。 2管道防腐层检测方法
目前,国内最常用的防腐层检测技术有:皮尔逊检测法(PS)和交流电流衰减法(PCM)两种。直流电位梯度检测法(DCVG)、CIPS与DCVG联合检测方法、杂散电流测绘仪一SCM等3种技术是近年来发