工程建设与设计
射线屏蔽防护层设计
ThePrefabricatePipingofNuclearPowerEquipmentManufacturing
王超
(中国中元国际工程公司,北京100089)
WANGChao
(China IPPR IntemationalEngineeringCorporation, Beijing 100089, China)
[摘要】目前射线源作为射线检测用源被广泛应用,根据国家职业卫生标准GBZ132-2008《工业射线探伤防护标准》,在射线防护设计过程中,须对屏蔽防护层进行计算,控制防护区域的边界值,同时对屏蔽防护区域进行有效的监控与检测。在实际生产工作过程中,并在外部环境允许的条件下,应适需增加防护距离和屏蔽防护层厚度,有效保护射线检测工作人员及周边人页安全。
[Abstract ]Thc y-ray source is currently widely used as a source of radiation detection, According to the national occupational health standards“Industrial y-ray protection industry protection standards" (GBZ132-2008),itis required to do the calculation of the protection shield during the designing ofradiation protection, control the boundary of the shielding area, and in the meantime monitor and test the shielding protection area. In the real production work, if external conditions allow, should increase the protectivedistanceandthethicknessofprotectionshieldtoeffectivelysecurethesafetyoftheonsiteand surroundingpersonne 关键词]y射线;射线屏蔽设计;无损检测
[Keywords y-ray; design ofradiation shielding; NDT
【中图分类号】TU234 1引言
【文献标志码]B
目前部分生产制造厂及大型石化装置建设现场,对于产品的无损检测,考虑生产习惯、便携性及曝光速度较快等优势,经常采用射线源作为射线检测用源。
射线源作为在相当一段时期内存在的放射性射线源,其安全屏蔽防护愈加重要。根据国家职业卫生标准GBZ 132一2008(工业射线探伤防护标准》,进行有效的屏酸计算和射线防护设计。
2屏蔽防护计算依据
【作者简介】王超((1980~.男,北京人,工程师,从事工程设计,(电子信箱)wangchao@ippr.net。
50
万方数据
【文章编号】1007-9467(2012)06-0050-02
射线探伤室的屏蔽墙厚度应充分考虑直射、散射和屏蔽物等各种因素。在进行屏获防护微设计时根据国家职业卫生标准GBZ132—2008《工业射线探伤防护标准》,剂量约束值可取为0.1mSv/a~0.3mSv/a,并要求探伤室屏蔽防护墙外 30cm处空气比释动能率不大于2.5μGy/h;无迷路探伤室门的防护性能应等同于同侧墙的防护性能。
根据探伤室周围环境,正常生产状况下,探伤室周围没有公众人员长时间停留。因此探伤室周边环境保护与控制目标见表1。
表1主要环境保护目标与控制一览表
序号保护对象
放射性工作人员
公众
保护内容年有效剂量
控制目标
年有效剂量不大于5mSv 年有效剂量不大于0.3mSv
不同种类的射线源由于其射线能量不同,对材料的衰