高烈度区多层结构抗震分析与选型设计
建筑与结构设计
Aretirtarafand
Anti-seismic Analysis and Structure Selection Design of Multi-storey Structure
inHighIntensityRegion 陆长生,黄希民,孙海涛
(新疆石油工程设计有限公司,克拉玛依834000) LU Chang-sheng,HUANG Xi-min,SUNHai-tao
(Xinjiang Petroleum Engineering Co.Ltd.,Karamay 834000,China)
【摘要】结构安全是工程设计中保证建筑安全的重要内客,钢筋混凝土框架结构以其造价低、平面布置灵活、易于设置大空间等优点,在工业与民用建筑中被广泛应用,钢筋混款土框架结构侧向度小,在抗震设防高烈度区其内力、侧移较大,易出现二阶效应,节点域抗剪超限、层间位移角难以控制等问题,论文结合哈萨克斯短9度(0.4g)Ⅱ类场地的具体工程,对抗案设计的要点及常见同题进行了设计分析,可为类似工程的设计提供参考。
[Abstract ]Thestructures must bedesignedinsafety. Thereinforcedconcrete structure is widelyusedin industrialand civilbuildings because ofits low cost,flexible layout and easy to set up large space, However, the reinforced concrete frame structure also has some problems, such as smallateral stiffness, the larger intemal force and the larger lateral displacement in high intensity area, obvious secondorderffect,shearresistanceoverduein thejoint area,and inter-storydisplacement angledifficult tocontrolandsoon.Themair points of the anti-seismic design and the common problems will be analyzed and summarized combing with the specific project of9
degrees(0.4g) and IIsiteinKazakhstan.It canprovidereferenceforthedesignofsimilarprojects inthefuture.【关键词】高烈度区;结构选型;抗袁设计;push-over分析
[Keywords Jhigh intensityregion; structure selection;anti-seismie;push-overanalysis
【中图分类号】TU352.11
【文献标志码]A
[DO1]10.13616/j.cnki.gcjsysj.2017.12.004
1引言
【文章编号】1007-9467(2017)12-0021-04
型、抗震分析设计着手,深人分析高烈度区提高结构抗震性能
地震具有突发性,至今可预见性仍很小,是各类自然灾害中最严重的灾害之一。避免悲剧的发生,离我们最近的莫过于建筑物的抗震设计。高抗震设防烈度区简称高烈度区,主要指设防烈度在8度(0.20g、0.30g)和9度(0.40g)及以上的地区。该地区最大特点为地震激励下结构体系的地霞作用效应较大,使得设计中可能出现层间位移角超限、节点域抗剪超限、超配筋等现象,这对抗囊十分不利。本文从概念设计、结构选
【作者简介】陆长生(1990~),男,山东鄞城人,工程师,从事结构设
计与研究。万方数据
的要点与措施。
2抗震设计方法
建筑抗震设计中概念设计能把握抗震设计的总方向,抗震计算能为抗震设计提供定量手段,构造措施以加强结构薄弱环节,从而保证抗震计算的结构有效性。我国采用“三水准,两阶段的抗震设计方法,第一阶段按第一水准多遇地震下各种效应的组合验算结构的承载能力和弹性变形,从而满足小振不坏;第二阶段按第三水准罕遇地震下的效应验算结构的弹塑性变形,从而满足大震不倒;通过良好的基本构造措施可以满足第二水准中震可修的要求。
21