故障分折 Fault Analyris
C95055MX3HP型空压机排气温度高故障分析与处理
李继豪,黄万庆,汪文振
(中国石油独山子石化分公司炼油厂第二联合车间,新疆独山子833600)
[摘要]:对C95055MX3HP型空压机排气温度高产生的原因从门型密封垫、冷却器结构、循环水系统等方面进行分析,采取措施,取得了明显的效果,积累了同类机型的运行维护和流程设计经验。
[关键词]:空压机;排气温度;冷却器中图分类号:TH453
文献标志码:B
文章编号:1006-2971(2014)02-0057-03
Fault Analysis andTreatment forHighDischargeTemperature inC95055MX3HPTypeAir Compressor
LI Ji-hao,HUANG Wan-qing, WANG Wen-zhen
(No.2 Joint Workshop, Refinery Plant, China Petroleum Dushanzi Petrochemical Company Branch, Dushanzi 833600, China
Abstract:This paper has analyzed the reason of high discharge temperature in C95055MX3HP type air compressor from the points of doortype seal gasket, structure of cooler and water circulating system, The corresponding measures are adopted,significant effect is
achieved and the experiences of operating maintenance and process design for similar types of compressors are summarized Key words: air compressor; discharge temperature ; cooler
1引信言
独山子石化公司1000万t/a炼油项目空压站共引进3台英格索兰(CENTAC)C95055MX3HP型离心空压机,3级压缩,流量9000Nm/h,排气压力0.85MPa(G),1~3级全采用内置管壳式冷却器,流程简图如图1。该压缩机担负着1000万t/a 炼油所有装置的仪表风和工业风的供应,在生产中发挥着至关重要的作用。对空压机来讲,压缩机的压缩能力主要受各级排气温度影响,而冷却器的冷却效果决定了排气温度,因此冷却器运行
情况对压缩机压缩能力至关重要。 2.故障概述
该压缩机自投用以来实际加载时间不到 3000h,与另外2台压缩机超过10000h的加载时收稿日期:20130930
题2014年02期(总第244期)
间相比,该机的运行时间较短。除了3台压缩机实际一开两备,A机备用时间较长外,加载一段时间后一级排气温度就会出现持续升高的情况,接近报警和联锁停机值,是制约该压缩机长周期运行的主要原因。表1列举了该机组各级冷却器排气温度报警值和联锁值设置。
故障分析 3
3.1压缩机冷却器冷却水侧门型密封胶垫故障率高的问题
CENTAC压缩机的冷却器采用的是内置式设计,因此机组结构紧凑、占地面积小,冷却水在进入冷却器后依靠进口接口处的门型密封胶垫将进水侧和排水侧分开,该机组原厂设计是采用合成胶水将门型胶垫粘贴在冷却水接口处的外壳上。该门型密封胶垫故障率高的主要表现为:门型垫密封失效,原因有以下2点:(1)安装时接触面
压缘机技术57 Compressot