3TYS89+2TYS60型氧压机的故障修复索全宝
(安阳钢铁集团有限责任公司,河南安阳455004)
[摘要]:2013年设备检修过程中发现氧压机的高低压缸出现较为严重的锈蚀,这对氧压机的安全运行构成了重大安全隐惠,为了保证人员、设备的安全,对氧压
机进行了及时的修复,详述了引起设备间题的原固和设备的修复过程。[关键调]:3TYS89+2TYS60:氧压机:铁绣
中图分类号:TH45
文献标志码:B
文章编号:1006-2971(2014)05-005903
FaultRecoveryof3TYS89+2TYS60OxygenCompressor SUO Quan-bao
( Anyang lron & Steel Group Co., Lad., Anyang 455004, China)
欧障分析 Fault Analysis
液嘉经轻杜发城自级
Abstract:lt was found serious corrosion appeared in high and low pressure eylinder of the oxygen eompressor during the maintenance in 2013, which seriously impacted the safety of the oxygen compressor. In order to ensure the safety of the company personnel and e-quipment, the oxygen compressor is repaired in time. This paper specified the reasons caused the equipment problems and the re pairing process in detail.
Key words: 3TYS89+2TYS60; oxygen compressor; rust
1引信
安钢制氧厂有2套14000制氧机组,型号均为3TYS89+2TYS60,分别投产于1996年8月和 2001年8月,是安钢生产的重要供气机组。该型号的氧压机系由一台电机拖动,分2个压缩缸,低压缸为6级压缩,高压缸为4级压缩;高、低缸串联,分别由2台增速机(低增高增)直接驱动。氧压机气体冷却器共5段,均是气走管程,水走壳程,横列于压缩机下方的设备基础上,机
组是等温压缩型压缩机。 2问题的发现
2013年9月9日~13日对2#14000机组进行年度系统计划检修,检修过程中(9月11日)对氧透的高(9.182t)、低压缸(5.552t)进行了拆
收稿日期:2014-0320
照2014年05期(总第247期)
盖,发现低压缸内壁有严重的锈蚀,缸体内部的镀铜均腐蚀脱落,高压缸缸体内壁亦有不同程度的金属腐蚀;将冷却器封头拆开,检查发现冷却器I段和耳段管束体有泄漏,判断应该是冷却器芯子漏水,最终导致压缩缸的锈蚀、失效。该氧压机自投产至今已运行13年,该问题系氧压机组的重大设备安全隐患。
原因分析
3 3.1
冷却器泄漏原因分析
(1)该机组自投产已经运行13年,在整个生产过程中,冷却器芯子壳程一直充满冷却水,冷却水加有具有一定腐蚀性的药液,由于长时间的运行,势必会在壳程的某些死角残存些泥沙,随时间的延长,积存污物越来越多,这些均会对冷却器管束造成腐蚀,甚至将管束的某些薄弱位置腐蚀透,造成冷却器漏水。
压缩机技术59 Compressoc