使用维修 Sersior&Maintetonce
往复压缩机气量调节气阀顶开力设计李颖,洪伟荣
(浙江大学化工过程机械研究所,浙江杭州310007)
[摘要]:针对往复压综机部分行程顶开进气阅气量调节方法,分析推导了排气量计算公式,确定了被动式气量调节比例与气阅项开力之间的数值关系。基于MATLAB的GUI功能,
设计了用户界面,为快速准确的完成气阀项开力设计提供一种可行的方法。[关键词]:往复压缩机;气量调节;排气量数值计算;气阔项开力;用户界面
中图分类号:TH457
文献标志码:A
文章编号:1006-2971(2015)020030-03
DesignofPressing-ofrForceinReciprocatingCompressorCapacity Regulation
LI Ying,HONG Wei-rong
(Institute of Process Equipment, Zhejiang University, Hangzhou 310007, China)
Abstract:This paper analyzed and deduced the capacity formula of the regulation method with depressing suction valve in reciprocating compressor, The numerical relationship between regulation ratio and pressingoff force was determined. Based on MATLAB GUI func-
tionality, the user interface was designed for providing a feasible method for accurately and rapidly determining regulation program. Key words: reciprocating compressor; capacity regulation; capacity numerical computation; pressingoff force; user interface
引信 1
往复压缩机具有排气压力广、热效率高、适应性强等优点,已成为石化行业不可缺少的主要设备。现今,随着企业生产弹性的增大,对压缩机气量调节的要求也越来越高。部分行程项开进气阀气量调节,节能效果好、调节范围大、经济效益显著,是往复压缩机气量调节的一种理想方法。对于气阀顶开方案,在国内流行的有被动式项开和主动式卸荷两种方法川。相比于主动式,被动式调节方法有着执行机构简单、实施方便快捷、调节成本低等诸多优点,通过与全行程顶开进气阀调节的合理结合可实现30%~100%的无级调节,因此有着较大的推广空间。本文旨在通过数值计算确定被动式气量调节比例与执行机构顶开力之间数值关系,并利用软件工具设计直观的用户界面。
收稿日期:20140922 30lcmp技m
压勤技术
2调节原理
部分行程顶开进气阀调节方法是在进气完毕后强制顶开吸气阀,气缸内部分气体在活塞的推动下回流至进气管路,仅对剩余气体进行压缩从而实现排气量的调节(如图1所示)。被动式顶开方式,是通过执行机构对进气阀阀片施加一个大小可调的顶开力,在吸气行程结束时使进气阀片持续项开,面在气体回流过程中,当气缸内气体压力足以克服顶开力时气阀被关闭。
正常工况调节工况
活塞行程
图1顶开进气阀气量调节原理