您当前的位置:首页>论文资料>办公建筑中空调形式对室内外PM2.5浓度相关性的影响

办公建筑中空调形式对室内外PM2.5浓度相关性的影响

资料类别:论文资料

文档格式:PDF电子版

文件大小:1.62 MB

资料语言:中文

更新时间:2024-11-22 10:25:38



推荐标签:

内容简介

办公建筑中空调形式对室内外PM2.5浓度相关性的影响 第39第4期 2017年8月
土水建筑与环境工程
Journal of Civil,Architectural &. Environmental Engineering
doi:10. 11835/i. issn., 16744764. 2017. 04. 001
Vol. 39 No. 4 Aug.2017

办公建筑中空调形式对室内外PM2.5浓度
相关性的影响
郑洁,张雨,姚大军,黄育华
(重庆大学城市建设与环境工程学院,重庆400045)
摘要:室外PM2.5可通过新风及国护结构缝隙渗透至室内,室外PM2.5较高时尤为明显,结果导致室内空气中的PM2.5浓度上升。为了研究空调形式对室内外PM2.5浓度相关性的影响,在 2015年夏季对重庆某办公建筑中采用不同空调形式的室内外PM2.5浓度进行了实测。实测结果发现:集中式空调、分体式空调和非空调房间室内外PM2.5浓度比变化范围分别为0.59~0.76、 0.47~~0.76、0.71~0.91。室内外PM2.5浓度相关性系数的排序为:集中式空调环境(0.94)>非空调环境(0.92)>分体式空调环境(0.77),研究结果表明,办公建筑的空调形式,对室内外PM2.5 浓度的相关性有影响。
关键词:PM2.5;空调形式;线性拟合;相关性系数办公建筑
中图分类号:X513
文献标志码:A
文章编号:1674-4764(2017)04-0001-05
Influence of air conditioningform onthe correlation of indoorand
outdoorPM2.5 concentration in officebuilding
Zheng JieZhang Yu,YaoDajun,Huang Yuhua
(Faculty of Urban Construction and Environmental Engineering Chongqing University,Chongqing 400045,P. R. China)
Abstract: Outdoor PM2. 5 could penetrate through fresh air and the wall gap into the room especially when outdoor PM2. 5 is particularly high, which lead to the rapid rise in the indoor PM2. 5 concentration. To determine the influence of the air conditioning system form on the indoor and outdoor PM2.5 concentration, the PM2. 5 concentration in the room with different air conditioning forms is measured in the summer of 2o15, which is in an office building in Chongqing . The measured results show that: the range of the indoor and outdoor PM2. 5 concentration ratio is 0. 59~0. 76, 0. 47~0. 76, and 0. 71 ~0. 91, respectively when the air conditioning system is . The relationship of indoor and outdoor PM2. 5 concentration correlation coefficient is centralized air conditioning environment (o. 94) > non air conditioning environment (0. 92) > decentralized air conditioning environment (0. 77). The results show that air conditioning form in office building has the effect of on indoor PM2. 5 concentration.
Keywords:fine particle matter (PM2. 5); air conditioning form; linear fitting; correlation coefficient; office building
收稿日期:2016-12-25
基金项目:国家重点研发计划(2016YFC0700705)
作者简介:郑洁(1960-),女,教授,主要从事建筑室内环境研究,(E-mail)jz187@cqu.edu.cn Received: 2016-1225
Foundation item:China National Key R &,D Program(No.2016YFCo700705)
Author brief:Zheng Jie (1960-), professor, main research interest: indoor environment, (E-mail)jz187@cqu. edu. cn 万方数据