JJF(鲁)117-2021
水泥中铬测定仪校准规范
Calibration Specification for Cement Chromium Meters
2021-12-04发布
2021-12-10实施
目 录
引言.........................................................................................................................................(1)
1 范围................................................................................................................................... (1)
2 概述................................................................................................................................... (1)
3 计量特性........................................................................................................................... (1)
3.1 线性误差........................................................................................................................ (1)
3.2 重复性............................................................................................................................ (1)
4 校准条件........................................................................................................................... (1)
4.1 环境条件........................................................................................................................ (1)
4.2 校准用标准物质及设备................................................................................................ (1)
5 校准项目和校准方法....................................................................................................... (2)
5.1 线性误差........................................................................................................................ (2)
5.2 重复性............................................................................................................................ (2)
6 校准结果表达................................................................................................................... (3)
7 复校时间间隔................................................................................................................... (3)
附录 A 铬标准溶液的配制方法..........................................................................................(4)
附录 B 水泥中铬测定仪校准记录格式(参考)..............................................................(6)
附录 C 校准证书内页格式(参考)..................................................................................(7)
附录 D 线性误差的不确定度评定示例..............................................................................(8)
1 范围
本规范适用于水泥中铬测定仪的校准。
2 概述
仪器应用于水泥中水溶性六价铬的测定,在水泥生产、建材检测等领域有广泛应用。测量原理为∶水泥中水溶性铬在一定条件下,与显色剂发生反应而显色,当单色光通过显色溶液,根据朗伯-比尔定律,吸光度与吸光物质的浓度成正比,通过光电检测装置将光信号转换为电信号,经过处理器后显示六价铬含量。仪器由进样单元、光学单元、检测单元和显示单元组成。
3 计量特性
3.1 线性误差
不超过±10%。
3.2 重复性
不超过1.0%(相对标准偏差)。
以上计量特性要求仅供参考,不作为判定依据。