摘要:制备了氮掺杂石墨烯为修饰电极,对双酚A(BPA)进行了电化学检测。实验表明,BPA在+0.2-+0.8V扫描电位范图内,有一个不可递的氧化还原峰出现。不同扫速的循环伏安行为发现,BPA的电化学氧化是一个由吸附控制的电极反应过程。BPA的浓度在4.0x10-~4.0x10*mol/L范围内与其氧化峰电流呈线性关系,检出限达到1.33×10*mol/L(S/N=3)。该电极用于检测各种塑料中的BPA含量,回收率在95.93%~ 103.5%之间,结果令人满意。
关键调:氮掺杂石墨烯;双酚A;化学修饰电极
DetectionofbisphenolAbasedonnitrogen-dopedgraphemesensor
Xu Zhen-ning, Wang Mo, Yin Huan-shun, Ai Shi-yun'
(College of Chemistry and Material Science, Shandong Agricultural University, Taian 271018, China)
Abstract: A nitrogendoped graphene (NRr) biosensor was modified glassy carbon electrode (GCE) and it has good electrocatalytic activity to electrooxidation of bisphenol A (BPA). The cyclic voltammogram (CV) of BPA on the modified electrode exhibits a well defined ireversible anodic peak and this oxidation signal was used to determine BPA. Under optimum conditions, the oxidation peak current was proportional to BPA concentration in the range of 4.0× 10- to 4.0× 10 mol/L and detection limit of 1.33 × 10* mol/L(S/N=3). The proposed method was successfully applied for detection of BPA in plastic products.
Key words: nitrogen- doped grapheme; bisphenol A; chemically modified electrode
相色谱法(HPLC)!)、气相色谱-质谱联用法(GC/
0引言
双酚A (Bisphenol A,BPA)是重要的有机化工原料,主要用于生产聚碳酸酯、环氧树脂、不饱和聚酯树脂等多种高分子材料。在塑料制品的制造过程中,添加双酚A可以使其具有无色透明、耐用、轻巧和突出的防冲击性等特性,因此广泛用于罐头食品和饮料的包装、奶瓶、水瓶等数百种日用品的制造过程中。BPA能导致内分泌失调,威胁着胎儿和儿童的健康,所以需要建立种快速、灵敏、简便、准确地监测生产废水中双酚 A的方法。
目前报道的检测BPA的方法主要有高效液
MS)(2]、液相色谱质谱联用法(LC/MS)[3)、高效液相色谱-荧光法(4)、荧光传感器法15]、单扫描极谱法(6)、高效液相色谱-电化学法(7)等。这些方法需要复杂的、多阶段的分析过程,面且耗时,仪器试剂昂责,需要专业操作人员和繁项的预处理,难以现场检测。综上所述,研究一种检测快速、数据可靠的BPA分析方法是非常必要的。
电化学方法(尤其是结合化学修饰电极)具有灵敏度高、响应速度快、线性范围宽、仪器低廉、操作简使和成本低展的特点,目前已经成为一种重要的分析手段。双酚A在电极上的化学行为研究较多,但是用化学电极(或修饰电极)对双酚A
基金项目:国家自然科学基金(No.21075078,21105056)资助项目*通讯联系人,Email;ashy@sdau.edu.cn