某340MW机组基于风机选型软件的
一次风机节能改造分析
衣心亮”,谷增义”,刘亮亮”,张健”
(1.大唐东北电力试验研究所,长春130012;2.西安格瑞电力科技有限公司,西安719400)摘要:某340MW机组锅炉配有两台一次风机,其运行效率较低,运行电流明显高于同类型机组,存在非常严重的能量浪费问题。基于风机选型软件,对其进行了改造选型工作,在保证其出力不变的情况下,两台-次风机每年实现节约电费65.912万元。
关键调:风机选型软件;风机选型;次风机;节能改造
3文献标志码:B文章编号:1009-3230(2018)05-0028-04
中图分类号:TK229.3
Analysis of Energy SavingReconstruction ofPrimaryFanBased
onFanSelectionSoftwareina340MWUnit YI Xin -liang, GU Zeng yi, LIU Liang liang, ZHANG Jian
(1.Datang Northeast Electric Power Test and Research Institute,Changchun 130012, China;
2. Xi'an Green Power Technology Co., Ltd. Xi'an 719400, China)
Abstract: A 340 MW unit boiler is equipped with two primary fans, its operation efficiency is low, the operating electric current is obviously higher than that of the same type of unit, a large amount of energy is wasted seriously. Based on the fan selection software, transformation and selection will be operated. At the same time,in the condition of ensuring its output unchanged, two sets of primary fan can achieve annual savings of 659. 12 thousand yuan.
Key words: Fan selection software; Fan selection; Primary fans; Energy saving transformation
0引言
电力行业有引风机、一次风机、送风机、排粉风机等多类风机,其功率往往在500~2000kW,属于耗能大户。机组在进行风机选型时,主要使用excel表格等进行计算,许多参数取决于设计人员自身的经验,选型效果参差不齐。部分设计人员由于不了解烟风系统沿程设备阻力经验数值,在参数选择时为保证安全性,裕量参数选取偏大,造成了风机实际运行点偏离设计点,长期运行在低效区域,存在非常严重的能量浪费。国内机组风机调研情况显示,目前有60%以上的风机运行
收稿日期:20180302修订日期:201804-11
作者简介:衣心亮,男,从事热能工程方面技术研究及管理
工作。
万方数据
效率较低,每时每刻都在浪费着大量的电能。 1设备概况
某340MW机组锅炉型号为HG-1025/18.2-YM6,是由哈尔滨锅炉厂制造的亚临界控制循环汽包炉、单炉膛、一次中间再热、平衡通风、钢炉架、露天布置、固态排渣、T型烟煤炉。烟风系统设计采用两台动叶可调轴流送风机和两台动叶可调轴流式引风机平衡通风,空气预热器为三分仓容克式,两台单吸双支承离心式风机,配备两台双室四电场电除尘器。每台炉配备两台型号为2008B-1065离心式一次风机,采用液力耦合调速方式运行。一次风机的运行效率偏低,电流明显高于同类机组,因此,有必要对一次风机进行改造,使风机与系统更加匹配,并可以大幅提高一次风机的实际运