摘要:文中以某电厂1000MW超超临界机组的设计和运行参数为基础,论证了三合一风机采用汽轮机驱动的可行性;并与采用电机驱动方案进行技术经济比较,推荐经济效益更优的凝汽式小汽轮机驱动引风机方案。分析结果表明:大容量引风机采用小汽轮机驱动后,避免了电动引风机造成的启动电流过大,厂用电电压等级需要提高等问题,显著降低了厂用电率。
关键词:汽轮机驱动;引风机;厂用电率
中图分类号:TK229.3文献标志码:B
文章编号:1009-3230(2012)04001305
DiscussiononTechnicalEconomyofTheTwoDrivingModesof
TheUltra-superitical1OOoMwUnitInducedFan
XIE Xin-yan', LU Sheng-kuan?
13
(1.State Nuclear Electric Power Planning Design & Research Institute,Beijing 100095,China;
2.China Datang Technologies & Engineering Co.,Ltd, Beijing 100097, China)
Abstract: Based on the design and operation parameters of the ultra-superitical 1000MW unit, the fesibility of steam turbine-driving induced fan has been analyzed in this article by comparing the economic efficiency of motor-driven mode and steam turbine-driven mode, The data shows that steam turbine-driven induced fans mode can avoid the start-up problems caused by the large capacity fans and remarkably lower the power consumpition rate of station service.
Key words:Steam turbine-driven; Induced fans; Power consumpition rate
0引言
随着火力发电厂机组蒸汽初参数的提高、超超临界机组在国内逐渐增多。同时,高参数、大容量机组所配辅机的容量也随之增大。常规配置中,引风机均采用电动机驱动,电机容量增大后带来了厂用电增加、启动电流大,厂用电电压等级需要提高等问题。近年来,大功率的电站辅机采用电动机驱动还是小汽机驱动,越来越多地受到人们关注。锅炉给水泵采用小汽轮机驱动后,引风机已成为厂用电最大的用户。合理选择引风机的
收稿日期:2012-03-11
修订日期:2012-0327
作者简介:谢新燕(1978-),女,工程师,主要从事火力发
电厂热机专业设计等方面的工作。
万方数据
驱动方式成为电站精细化设计的主要内容之一,对电厂安全、稳定和经济运行起着重要的作用。
内蒙某2×1000MW超超临界空冷燃煤机组采用当地褐煤,采用中速磨正压直吹式冷一次风机制粉系统,同步建设脱硫、脱硝设施,选用静电除尘器,引风机与脱硫增压风机合并。根据煤质及锅炉技术条件,工程推荐采用2×50%容量的静叶可调轴流式风机。经燃烧制粉计算,单台引风机TMCR工况轴功率达到6000kW,TB点轴功率达到9051kW。
文中对电动机驱动引风机和凝汽式小汽机弱动引风机两个方案进行技术经济分析比较,同时