20
doi;10.3969/j. issn.1009 3230.2016.09.007
应用能源技术
2016年第9期(总第225期)
燃煤锅炉净烟气余热深度利用方案研究
张涛
(京能(赤峰)能源发展有限公司,内蒙古赤峰024007)
摘要:采用抗腐蚀材料换热器对燃煤锅炉净烟气余热进行深度回收和利用,对实现我国燃煤机组节能减排具有重要意义。文中以氟塑料换热器为例,针对电站锅炉余热的深度回收阐述了该方案的可行性和经济性,并对该过程的凝水回收进行了说明。
关键词:余热深度回收;氟塑料换热器;凝水回收
中图分类号:TK229.4文献标志码:B文章编号:1009-3230(2016)09-0020-03
Study on ResidualHeatRecovery of FlueGas fromCoal FiredBoiler
ZHANG Tao
(Jing Neng (ChiFeng) Energy Developments Co.,Ltd.Chifeng 024007,Inner Mongolia,China) Abstract:Theuse of corrosion resistant material for heat exchanger of coal-fired boiler flue gas waste heat recovery and utilization,to achieve the energy saving emission reduction of China's coal fired units is of great significance. Taking the fluorine plastic heat exchanger as an example, this paperexpounds thefeasibility and economy ofthe project, and illustrates thefeasibilty and economy of thismethod
Key words: Residual heat recovery; Fluorine plastic heat exchanger; Condensate recovery
0引言
排烟热损失是电站锅炉各项热损失中最大的一项,一般在5%~12%。近年来,国内外许多电厂为降低电站锅炉排烟温度进行了大量改造,其中鳍片管省煤器、螺旋肋片管省煤器应用较为广泛。通常将低温省煤器布置在空预器与静电除尘器之间或引风机与脱硫塔之间,使排烟温度从 130~150℃降至90℃左右。利用该部分热量加热凝结水或加热一二次冷风,可以提高电厂效率 0.6%以上,降低发电煤耗2~3g/kW·h。[1-2]这不仅有效地利用了烟气余热,而且烟气温度在很大程度上提高了脱硫效率。然而在烟气石灰石-湿法脱硫系统中,脱硫系统排出的烟气温度在50℃左右,由于该温度处于烟气酸露点以下,无法使用以
修订日期:20160820
收稿日期:201607-18
作者简介:张涛(1972-)男,本科,工程师,设备自动化
方向。
万方数据
上换热设备收集烟气余热[3]。对于脱硫后的烟气余热利用,需考虑设备的低温腐蚀间题。因此,对于脱硫后净烟气余热深度回收利用,就需要采用新型的抗腐蚀烟气换热器来解决此问题。
采用湿法脱硫的锅炉从脱硫塔出来的净烟气中水蒸气含量较大,主要来自煤中的水分和脱硫浆液中的水分。此时烟气中的水蒸气处于湿饱和状态,若能够在脱硫塔后安装烟气换热器使烟温进一步降低,则烟气的饱和水蒸气将释放大量的凝结潜热,同时从烟气中分离出来。分离出的水具有一定的酸性,且氟离子含量较少,可再用于脱硫塔,全部或部分替代脱硫补水,实现水的回收利用。这对北方水资源不丰富的地区具有重要意义。
目前使用的耐腐蚀换热器形式主要有:ND 钢、防腐涂层、氟塑料材质(4-5)。文中主要对氟塑料材质换热器的使用加以说明。