2013年第3期(总第183期)
doi:10.3969/j. issn.1009 3230.2013.03.005
应用能源技术
国产690t/h循环流化床锅炉节能减排运行研究
刘志强
(神华国能(神东电力)集团公司,北京100033)
摘要:对某厂国产690VhCFB锅炉进行冷态试验、热态试验和运行优化调整。根据冷态试验结果,对锅炉的风量测量元件进行标定。通过热态试验结果,修正氧量场、温度场的测量数据。通过运行优化调整试验,实现锅炉效率的提升,其中在高负荷条件下的锅炉效率相比调整前提高0.83%,并且使得主要风机运行电流有所减少,实现锅炉的安全稳定高效运行,为同等级循环流化床锅炉的优化调整提供参考。
关键词:CFB锅炉;冷态试验;热态试验;运行调整中图分类号:TK229.6:
文献标志码:A:
文章编号:1009-3230(2013)01-0017-06
StudyonEnergyConservationofaDomestic
690t/hCFBBoiler
LIU Zhi -qiang
(Shenhua of Guoneng(Shendong clectricity)Group CompanyBeijing,100033,China) Abstract : This paper is aiming at a domestic 69O t/h CFB Boiler of one power plant, to do cold test, hot test and operating adjustment. The cold and host testing results can help to calibrate air flow measuring system,to adjust the oxygen field and temperature field.By operating adjustment, combustion efficiency was improved by 0. 83% at high load condition, the current of fans decressed,
which can be the reference of the operating of the same type CFB boilers. Key words: CFB boiler; Cold test; Hot test; Operating adjustment
0引言
循环流化床燃烧是最近几年在国内大规模应用的一种洁净煤利用技术,具有燃料适应性广、负荷调节性好、燃烧效率高等优点,受到了国内众多用户的青,占有了相当的市场份额。但是由于设计经验的欠缺以及运行水平的限制,国内目前投运的不少循环流化床锅炉存在运行经济性较低的问题[1-2]。
文中主要针对某厂国产690VhCFB锅炉进行了试验研究,通过冷态试验、热态试验和运行优
收赖日期:2013-01-18
修订日期:20120210
作者简介:刘志强(1965-),男,工学硕士,高级工程师,现
任神华国能(神东电力)集团公司副总经理。
万方数据
17
化调整等方式,实现锅炉设备的最佳运行方式,以提高锅炉效率、降低厂用电,从而提高设备运行的经济性,并同时保证锅炉更加安全稳定运行[3-4]。
锅炉设备规范 1
厂CFB锅炉为SG-690/13.7~M451型超高压再热型锅炉,锅炉总图如图1所示,采用单锅筒自然循环、集中下降管、平衡通风、绝热式旋风分离器和滚筒冷渣器,锅炉主要技术规范见表1,锅炉设计煤种及校核煤种参数见表2。