28
doi :10. 3969/j. issn. 1009 3230. 2014. 09.007
应用能源技术
2014年第9期(总第201期)
优化控制在135MW循环流化床锅炉的应用
潘志刚,刘学武
(中电投蒙东能源通辽盛发热电有限责任公司,内蒙古通辽028051)
摘要:目前国内的循环流化床自动化投入率普遍较低,对控制策略提出了更高的要求,以增强电厂的整体效益和竞争力。但由于循环流化床机组特有的燃烧特性,常规PID控制策略很难实现循环流化床锅炉燃烧自动控制,导致循环流化床锅炉机组的自动投入率低。优化控制系统在循环流化床锅炉燃烧控制的应用,为此提供了一种良好的解决逢径。
关键词:优化控制系统;无辨识自适应控制;循环流化床锅炉;分散控制系统
文献标志码:B文章编号:10093230(2014)09-0028-06
中图分类号:TK229.3
TheApplicationandPracticeofOptimizingControl
to Circulating Fluidized Bed Boilers
PAN Zhigang,LIU Xue-wu
(Tongliao Shengfa Power Generation Co.,Ltd, Zhongdian Toumengdong Energy Group
Co.,Ltd, Tongliao 028051, Inner Mongolia, China)
Abstract: Now, the input rate of automated circulating fluidized bed is prevailingly low. Thus, in order to promote the whole profit and competitive strength, the higher demand for DCS system is proposed. But, because of the peculiar combustion characteristics of circulating fluidized bed unit, it is hard to realize automated control of CFB boiler combustion by means of regular PID control strategy, which can lead to low rate of automated input of CFB boiler unit and the fail of boiler turbine cooperative control.In these cases, the application of optimizing control to CFB unit combustion control offers an effective resolution.
Key words: Optimizing control system XD APC; Identification free adaptive control; CFB boil-er;DCS
0引言
通辽盛发热电有限责任公司现有2台135 MW流化床机组,单元制方式。锅炉DCS采用北京国电智深控制技术有限公司的EDPF-NT系统,只有给水和减温水可以投自动,其余回路均手动操作(1-"]。具有循环流化床锅炉特有的热惯性大、煤质多变、各种变量强耦合等特性,锅炉燃烧具有大滞后、非线性等间题,很难实现燃烧过程的自动控制[4-5]。
收稿日期:2014-07-21
修订日期:2014-0811
作者简介:潘志别,男,内蒙古通辽市科尔沁区,工程师,从
事电厂生产管理方面的工作。
万方数据
CFB锅炉手动操作产生的问题 1
目前CFB锅炉燃烧自动控制系统基本未投运。而手动操作存在以下4个方面的问题:
(1)压力波动较大。问题是循环流化床锅炉运行普遍存在的间题,会导致设备损伤(特别是汽轮机),不利于机组长期运行,同时增加能耗。
(2)操作人员劳动强度大,增加人为失误,并且操作人员忙于一般运行,没有精力顾及提高机组运行经济性。
(3)手动操作方式,使得机组运行严重依赖于操