2011年第7期(总第163期)
应用能源技术
200MW循环流化床锅炉燃烧优化调整试验研究
李荣,李亚祥,解观栋”,黄中”
(1.神东电力有限责任公司,陕西榆林719300;2.神华亿利能源有限责任公司,内蒙古鄂尔多斯014300;3.西安热工研究院有限公司,陕西西安710032)
对循环流化床锅炉运行的影响,提出了适用于200MW循环流化床的参数要求,研究工作为提高循环流化床锅炉运行效率和节能减排积系了宝贵经验。
关键词:循环流化床锅炉;冷态试验;燃烧优化;调整试验;研究
中图分类号:TK229.6文献标志码:A文章编号:1009-3230(2011)07-0025-03
2oOMwCFBBoilerCombustionOptimizationand
AdjustmentResearch
LI Rong', LI Ya-xiang, XIE Guan-dong', HUANG Zhong
(1.hendong Power Co.,Ltd. Yulin 719300,China; 2.Shenhua Yili Energy Co.,Ltd.Ordos 014300,China; 3.Xian Thermal Power Research Institute Co.,Ltd. Xian 710032, China)
Abstract:This completed a 200MW CFB boiler and combustion tests of cold adjustment test optimization. It analyzed various factors on the impact of circulating fluidized bed boiler, proposed fo the parameters required 200MW CFB, researched to improve the efficiency of circulating fluidized bed boiler and energy savings gained valuable experience.
Key words:CFB boiler; Cold test; Combustion optimization; Adjustment test; Study
0前言
循环流化床锅炉是最近几年在中国得到飞速发展的洁净能源技术。据统计中国已经投人商业运行的循环流化床锅炉超过3000台,循环流化床锅炉业已成为我国火力发电领域的重要组成部分。但是受到燃用煤质差、运行经验欠缺等因数的影响,相当数量的循环流化床锅炉设备可用率低、运行经济性差,这些问题已经影响到了电力企业的安全生产和经济效益。
结合200MW循环流化床锅炉完成了冷态试验和燃烧优化调整试验。分析了炉壁总风量、氧量、床压等参数对锅炉运行的影响,通过燃烧优化
收稿日期:20110518修订日期:2011-05-27
作菌介:李荣(1972-),男,工程师,神东电力有限贵任公
司副总经理,从事循环流化床钢炉技术管理相关工作。
万方数据
25
调整提高了锅炉效率、降低了锅炉的运行风量、减少了主要风机运行电流。试验结果显示,锅炉效率相比试验前提高了0.84%,节能减排效果显著。
1锅炉设备概述
某厂200MW循环流化床由中国科学院工程热物理研究所设计、上海锅炉厂有限公司制造,锅炉为岛式紧身封闭布置、全钢结构、炉顶设置轻型钢屋盖,运转层标高为10m。锅炉采用单锅简自然循环、集中下降管、平衡通风、绝热式旋风气固分离器、循环流化床燃烧方式、滚筒简冷渣器,后烟并内布置对流受热面,过热器采用两级喷水调节蒸汽温度,再热器采用以烟气挡板调节蒸汽温度为主、事故喷水装置调温为辅。锅炉主要技术参数见表1。