24
应用能源技术
doi:10.3969/j. issn. 1009 3230.2014.10.007
2014年第10期(总第202期)
300MW循环流化床锅炉特殊工况下的
调整与环境因素分析
葛如明
(山西平朔煤研石发电有限责任公司,山西朔州036000)
摘要:文中针对第一批进口300MW循环流化床锅炉在某电厂中的运行与实践,提出了 300MWCFB锅炉在特殊工况下的调整方法与环境影响的关系,同时对新建大型循环流化床锅炉运行具有指导意义。
关键词:循环流化床锅炉;运行调整;环境因素
文献标志码:B文章编号:1009-3230(2014)10-0024-03
中图分类号:TK229.4.1
Analysisof theAdjustmentof3OOMWCirculatingFluidizedBedBoiler
underSpecialWorkingConditionsandEnvironmentalFactors
GE Ru ming
(Shanxi Institute of Mechanical& Electrical Engineering.Shuozhou 036000,Shanxi Province,China)
Abstract: In this paper, the first batch of imported 300 MW circulating fluidized bed boiler in a power plant in operation and practice, put forward the relationship between the adjustment method in special conditions of 30OMWCFB boiler and environment influence, also has guiding significance for
the operation of newly built large circulating fluidized bed boiler. Key words:CFB; Operation adjustment; Environmental factors
0引言
作为新一代的洁净煤燃烧技术,循环流化床(CFB)锅炉燃烧技术已在世界范围内得到广泛应用。目前面临越来越严峻的环境压力,国家新的环保标准于2014年7月1日即将开始执行,针对引进型技术的CFB锅炉,并结合作者多年从事电厂运行的经验,提出了300MW循环流化床锅炉特殊工况下的调整与环境质量存在必然影响的观点值得大家关注"]。
锅炉运行方式及参数介绍
某厂300MWCFB锅炉为上海锅炉厂有限公司引进技术生产的循环流化床、中间再热自然循
收稿日期:2014-08-10
修订日期:201409-10
作者简介:基如明:男,山西大同人,2007年毕业于太原电力
职业技术学院,在山西平朔煤石发电有限责任公司工作,助理工程师。
万方数据
环燃煤锅炉。
锅炉最大连续蒸发量:1060.6Vh。
额定蒸发量:1010.1Vh。过热蒸汽压力:17.5MPa。过热蒸汽温度:541℃。
低温再热蒸汽压力:4.03MPa。低温再热蒸汽温度:333℃。高温再热蒸汽流量:870.5Vh。高温再热蒸汽压力:3.824MPa。高温再热蒸汽温度:541℃。省煤器人口给水温度:279℃。锅炉保证效率:91%。
空气预热器:四分仓回转式。
炉膛热循环回路由炉膛、四个偏心布置旋风分离器、四个回料器、四个外置式换热器组成。排