万方数据
第5期 2012年9月
分析与检测
中
氮肥
M-Sized Nitrogenous Fertilizer Progress
钒一过氧化物比色法的测定条件探讨
牛富琴
(灵石中煤化工有限责任公司,山西晋中031303)
No.5 Sept.2012
【摘要】过氧化物比色法测定拷胶脱硫溶液中的钒比传统的氧化还原法效果好,适用于榜胶脱硫工艺的生产控制分析。为导求更快捷的分析方法,以五氧化二钒为分析对象,对过氧化物比色法的测定条件进行了操讨。采用新的测定条件后,节省了试剂,缩短了分析时间。
[关键词】格胶脱硫溶液;钒;过氧化物比色法
【文献标识码】B【文章编号】1004-9932(2012)05-0060-02
[中图分类号】TO016
DiscussiononTestConditionforVanadiumPeroxideDetermination
NIUFuqin
(Lingshi Zhongmei Chemical Industry Co.,Lud,Jinzhong 031303,China)
Abstract: Vanadium peroxide colorimetry is better than traditional reduction-oxidation mothod for vanadium determination in tannin extract solution.This method is suit for production control with tannin extract desulfurizing process. To find out more quick analysis method we have studied the test condition for vanadium peroxide colorimetry with V, O, as analyzing subject, concluded that the new method cost less test agents and spent less time.
KeyWords:tannin extract solution;vanadium;peroxidecolorimetry
目前,胶脱硫工艺在中小氮肥厂、炼焦、
城市煤气、环保等行业广泛应用,作为一种催化剂加人到考胶脱硫液中。快速准确地测定出烤胶脱硫溶液中的钒含量对于生产控制尤为重要。比色法测定拷胶脱硫液中的钒含量比传统的氧化还原法更快、更准确。常用的比色法有焦性没食子酸比色法和过氧化物比色法。焦性没食子酸比色法以焦性没食子酸为发色剂,发色酸度为 pH(7~8),但焦性没食子酸在碱性溶液中易被氧化,用于pH(8.5~9.2)的拷胶脱硫液的分析必然造成误差。过氧化物比色法以硝酸钾、硝酸预处理脱硫液,使硫析出后过滤,仍需减去滤液消光值来消除拷胶颜色的干扰。本文运用的过氧化物比色法用双氧水氧化拷胶脱硫溶液中的还
【收稿日期】2012-02-28
【作者简介】牛富琴(1974一),女,助理工程师,从事化工分析与检测工作。
原性物质,使溶液褪色完全,又以双氧水为发色剂,发色灵敏而且环保。为了得到简便实用的分析条件,进行了以下试验。
1方法 1.1原理
在碱性条件下,用双氧水将烤胶脱硫液中还原性物质及少量悬浮硫氧化为硫酸盐,并氧化拷胶使之脱色。在酸性条件下,加人适量双氧水,钒酸根中的[02-1为过氧基团【0′-取代, 生成红棕色的V(0,)3+,在波长450nm处用1
cm的吸收池测定吸光度。 1.2仪器
722型分光光度计,带有1cm的比色皿。 1.3试剂
硫酸1+1;双氧水30%;