第24卷第11期 2017年11月
仪器仪表用户 INSTRUMENTATION
核电站用温度仪表套管水压试验方案探讨
康文捷1,李向华2,杨晓波1,吴炎召1,李高文2
(1.重庆川仪十七厂有限公司,重庆400700:2.中广核工程有限公司,广东深圳518124)
EICVol.24 2017No.11
摘要:文章介绍了核电站用温度仪表套管的类型,分析了对其进行水压试验的目的和实际操作方法,并对该试验
的实际效果进行了分析,旨在探讨一种既能快速、准确检验缺陷,又利于工程实际的缺陷探测方案。关键词:核电站;温度仪表套管;水压试验
D01 : 10. 3969/j. i ssn. 16711041. 2017. 11. 012
中图分类号:TH811
文献标志码:A
文章编号:16711041(2017)11-004802
DiscussiononHydraulicTestSchemeforThermowellsWhichUsed
inNuclearPowerStation
Kang Wenjie,Li Xianghua',Yang Xiaobo",Wu Yanzhao",Li Gaowen
( 1.ChongQing ChuanYi Instrument No.17 Factory Co.,LTD_, Chongqing, 400700, China : 2.China Nuclear Power Engineering Co., Lid., Guangdong, Shenzhen, 518124, China )
Abstract: This essay introduces several types of thermowells used in the nuclear power plant, analyses the aims, the operating method and the actual effects of hydraulic testing, which aims to describe one fast, accurate and also engineeringconvenient defect examination resolution.
Key words: nuclear power station; thermowell; hydraulic testing
0引言
温度测量在现代工业精细控制中作为不可或缺的重要测量已越来越受到重视,在核电站“热-电”转化过程中也有着大量的使用,为了安全需要和便于在线更换传感器等要求,在核电站测量管道及罐体内部介质温度时,均采用了有套管结构的温度仪表
由于核电站工作介质的特殊性及核电站运营过程对于安全的谨慎,特别是三代核电机组大量取消旁路,直接在主回路测温的现状下,一且温度仪表套管(以下简称套管)出现泄漏、甚至断裂都极易造成严重的后果,故对温度测量用套管的质量提出了较高的要求。
套管设计时需要对其结构进行设计分析,确保其安全系数具有元余性及良好的可靠性,对于套管原材料的制造方法、性能参数也有着近乎苛刻的要求,套管加工时也均要求采用整体棒料机加工的方式
为了避免存在后期加工缺陷产品的非预期使用,在套管加工完毕后还需要进行一系列的检验和试验,如水压试收稿日期:20170728
验、表面渗透检验及X射线内部尺寸检验等检验和试验项目,进一步确保套管的品质。
文章主要讨论套管加工完成后的水压试验,对其试验方法、试验实现过程及试验效果进行分析、提出建议供核
电仪控设计及运营工程技术人员参考 1套管的类型
在核电站各工艺环节,由于测量介质特性及安装位置的差异,套管按其安装方式可分为如下几类,如图1所示。
焊接式结构套管主要适用于常规岛测量汽机及辅助单元各工艺回路的温度。由于测量处压力较高,均采用焊接式结构进行安装。
法兰式结构套管多用于海水冷却回路的温度测量,主要是基于海水腐蚀性强,后期需要更换的考虑,故而多采用法兰式安装结构,这种结构在核电站所用套管中数量最少
螺纹连接+密封焊接结构套管由于安装、拆卸较为方
作者筒介:康文捷(1969一),男,重庆北赔人,工程颈土,高级工程师,从事各种行业接眼式温度仪表的研究开发工作