列管材质对压缩机级间换热器结焦抑制效果的影响
姜颖,田蒙奎,王军,王国维,王昌敏,简万国
(1.贵州大学化学与化工学院,贵州贵阳550025;2.责州开磷(集团)有限责任公司,贵州开阳550300)
辅机应用 uoypayddy Cepy
挂片实验,综合各管材的传热效率,研究各种换热管材质的抑焦效果。结果表明:304不锈钢管的抑焦效果最好,其抑焦率
可以达到90.35%。该研究工作为换热管的选材提供了一定的理论指导。[关键词]:合成氨;换热器;换热管材质
5文献标志码:B
中图分类号:TH45
文章编号:1006-2971(2016)03-0047-03
Influence of TubeMaterial onCokingInhibitionEffect ofCompressor StageHeat Exchanger JIANG Ying', TIAN Mengkui, WANG Jun', WANG Guowei?, WANG Changmin’, JIAN Wanguo?
(1. School of Chemical and Chemical Engineering, Guizhou University, Guiyang 550025, China; 2. Guizhou Kailin (CROUP) Co., Lad., Kaiyang 550300,China)
aaaseeeassneseaee eral kinds of tube materials common used for chemical equipment to carry on the hanging pieces experiment under actual operations, combined with heat transfer efficiency of each tube material, to study the coking inhibition effect of each kind of material of heat ex-change tube. The result shows that the coke effect of the 304 stainless steel tube is the best, the coke rate can reach 90.35%. the
research work can provide a certain theoretical guidances for the material selection of heat exchange tube. Key words: synthetic ammonia; heat exchanger; material of heat exchange tube
1引言
贵州开磷息烽合成氨有限责任公司以半水煤气生产合成氨,产量60万a。在合成氨工艺中,为了使合成气达到合成所需的压力,需要逐级压缩。该公司压缩工段使用型号为6M50-345/314往复式氢氮压缩机,6组并联工作,每组均有6级(段)压缩,在各级压缩间采用列管式水冷方式简体材质为16MnR,列管材质为20#无缝钢管,冷却水走管程,合成气走壳程。在投入使用以来,存在级间换热器结焦的现象,前三段尤其明显,
收稿日期:2016-01-08
基金项目:贵州省工业攻关项目(贵州省科技厅(黔科合GY字[2012)
3052);社发攻关项目(黔科合SY字[2013]3078号;贵州科技创新人才团队(黔科合人才团队[2015]4004号)
2016年03期(总第257期)
结焦物聚集在管间,严重影响换热效果,导致换热器出口温度超标、压缩机压缩比降低,功耗提高。每3~4个月工厂就需对结焦堵塞严重的换热器进行拆装、抽芯并用高压水清洗,但效果并不理想,清洗后运行20天左右换热器出口温度再次超过设计温度40℃,半年左右要采用化学试剂进行比较彻底的清洗,虽清洗效果有所提高,但设备运行40天左右,出口温度再次超标,且化学试剂会对换热管造成一定的腐蚀。设备在投入使用2~3年后,由于焦垢及化学清洗剂对列管的严重腐蚀,使其无法继续使用只能进行更换,更换造成的直接费用每年高达上百方,闻接费用更是高达上于万元。压缩机级间换热器的结焦现象不仅影响换热设备的正常运转,直接影响整个合成氨工段的
压缩机技术47 Compresso