第38卷第8期
2010年8月【分析与测试】
聚氧乙烯
Polyvinyl Chloride
Vol.38,No.8 Aug.,2010
电石法氟乙烯单体中低沸物和高沸物含量的气相色谱法分析
候迎利“
(新璧中泰化学股份有限公司,新疆岛鲁木齐830009)
[关键词]PVC;氯乙婚单体;低沸物;高沸物;含量;测定方法;气相色谱法
[摘要]介绍了利用气相色讲测定电石法氯乙烯单体中高沸物、低沸物含量的方法。该方法准确度高,稳定性好,操作简单、快捷,有很高的使用价值。
[中图分类号】TQ325.3;TQ014
[文献标志码]A
[文章编号]10097937(2010)080036-02
Gas chromatography analysis on contents of highboilers and lowboilers
in vinyl chloride monomer produced by calcium carbide method
HOUYingli
(Xinjiang Zhongtai Chemical Co., Ltd., Urimqi 830009, China)
Key words: PvC; vinyl chloride monomer; low boilers; high boilers; content; determination method;gas chromatography
Abstract: A mcthod for the determination of contents of high boilers and low boilers in vinyl chloride monomer produced by calcium carbide method with gas chromatography was introduced. It was indicated that this mcthod was accurate,stable, simple,rapid and was worth using.
在电石法聚氯乙烯(PVC)树脂生产过程中,乙炔与氯化氢气体在转化器中合成的粗氟乙烯单体经过加压、降温后变成液态,其中主要含有乙炔、乙醛、反-二氯乙烯、1,1-二氯乙烷、顺一二氯乙烯、三氯乙烯、1,2-二氟乙烷等高沸物和低沸物,需通过高沸塔、低沸塔进行精馏处理。氯乙烯单体中低沸物、高沸物的含量对PVC树脂的质量有较大影响,高沸物乙醛和1,1二氯乙烷都是活泼的链转移剂,能够降低氯乙烯的聚合度及反应速度;低沸物乙炔会使聚合反应速率变慢,降低PVC聚合度,影响树脂的黏数"。笔者采用气相色谱分析方法对精馏前后的氯乙烯单体进行检测,分析其高沸物、低沸物含量的变化,以判断设备的运行状态是否正常、平稳。
1试验方法 1.1原理
用色谱柱将氯乙烯单体中各组分分离,以火,[收稿日期]2010-05-12
焰检测器(FID)来检测被分离各组分的浓度。在氯乙烯单体中,无论是氯乙烯本身还是高沸物或者低沸物都是碳氢化合物以及它们的衍生物,FID 对这些物质都有相应的响应。FID的工作原理是以氢气在空气中燃烧为能源,载气(Nz)携带被分析组分和可燃气(H,)从喷嘴进人检测器,助燃气(空气)从四周导入,被测组分在火焰中被解离成正负离子,在极化电压形成的电场中,正负离子向相反的电极移动,形成的离子流被收集极收集并输出,经阻抗转化和放大器放大(放大107~1010 倍)便获得可测量的电信号,再根据信号大小来测
定各组分的含量。 1.2仪器设备
7890F气相色谱仪、HW-2000色谱工作站[2),上海天美科学仪器有限公司。
[作者简介侠迎利(1981-),男,助理工程师,2004年毕业于新疆农业大学环境科学专业,现于新疆中泰化学股份有
限公司米东事业部从事质检技术和质量管理工作。 36