地下水源热泵系统对地下温度场的影响
UndergroundWaterSourceHeatPump SystemHastheInfluenceof Underground
TemperatureField
孟庆伟
(河南省地质矿产勘查开发局第一地质环境调查院,郑州450045)
MENGQing-wei
公用工程设计 Mie Chltiz Druig
(NO.1 InstituteofGeo-environment Survey,Bureau of Geoexploration and MineralDevelopmentof Hen,Zhengzhou 450045,China)【摘要】论文借助FEFLOW有限元程序建立水热运移模型,基于一些基本假设条件,采用数值模拟方法对郑州郑东某小区地下水源热泵系统与地下温度场演化进行研究,从长期地温场变化来看,井温度总体上升不明显,
[Abstract] Thispapermakes use oftheFEFLOW finite element program to establish water thermal migration model,and bases on some basic sumptions.The numerical simulation method was adopted to a district ofzhengzhouZhengdong underground water source beat pump system snd underground temperasture field evolution in research, from thelong-term geothermal field changes to sce,well temperature overall rise is not obvious
[关键调]热象;地下水;彩响
[keywords ]heat pump; groundwater;influence
【中图分类号】TU833*.3 1示范工程位置
【文献标志码]A
郑东某小区水源热泵系统应用工程位于郑州郑东新区中南部。在地热能利用规划适宜性分区方面属于一般适宜区,公共配套完善,位置优越,交通便利。
2地层与构造 2.1地层
郑东新区地层属华北地层区华北平原分区,地层由考到新有古生界寒武系(厚250~600m)、奥陶系(厚43.9~ 230.9m)、石炭系(厚2.7~98.3m)、二叠系下统(厚105~ 1260m)、中生界三叠系(厚度大于2000m)、新生界新近系(厚 2501140m)、第四系(厚3~105m),全区出联地层为第四系全新统。
【作者简介】孟庆伟(1978~),男,对南漏炮人,水工环地质工程师,
从事水工环地质研究,(电子信箱)hnsswyde126.com。万方数据
【文章编号】1007-9467(2013)01-0105-03 2.2构造
郑东新区位于华北陷(一级构造单元)中的开封坳陷(二级构造单元)的西南部,坳陷的形成及其中的构造展布受控于区域大地构造活动。
区内构造以北西向和近东西向断裂为主,主要是在区域内多次构造运动影响下形成的,它们和新构造运动一起控制着工作区的地热特征。大部分断裂均属基底断裂,错断了三叠系~奥陶系。此类断层自西南向东北分别呈东西向平行分布和北西向平行分布,造成基底呈阶梯状断落,形成许多断块,使上部第四系和新近系厚度变化较大。
区内新构造运动较发育,主要表现形式为升降运动和断裂活动。前者自全新世以来继续下沉,加上黄河带来大量泥沙的沉淀,使黄河河床高出堤外地面2~5m,形成闻明遐迩的悬
河。后者均发生在第四纪以前,形成一系列北西向的正断层。 3数学模型
鉴于地下水源热泵系统的运行特征,参考实际含水层结
105