您当前的位置:首页>论文资料>核电应急柴油发电机组辅助高温水循环泵抗震鉴定试验研究

核电应急柴油发电机组辅助高温水循环泵抗震鉴定试验研究

资料类别:论文资料

文档格式:PDF电子版

文件大小:3.7 MB

资料语言:中文

更新时间:2024-12-13 17:51:00



推荐标签:

内容简介

核电应急柴油发电机组辅助高温水循环泵抗震鉴定试验研究 第39卷(2017)第5期减振与降噪
柴油机 Diesel Engine
Vol.39(2017) No.5
核电应急柴油发电机组辅助高温水循环泵
抗震鉴定试验研究孙志宏”,郑忠伟”,李鹏涛”
(1.陕西柴油机重工有限公司,陕西兴平713105:2.中国核电工程有限公司,北京100840:
3.陕西柴油机重工有限公司西安电站工程分公司,陕西西安710077)
摘要:为验证某核电站应急柴油发电机组辅助用高温水循环泵的抗震性能,根据国家相关规范标准进行了抗震性能试验研究。采用白噪声信号作为输入激励,分别测试了高温水循环泵在抗震试验前后的固有频率和阻尼比:根据高温水循环泵具体位置选定对应的反应谱,进行了5次运行基准地震试验和1次安全停堆地震试验。试验结果表明:该型高温水循环泵有足够的抗震强度,能够在规定的地震条件下正常运行,满足抗震性能要求。
关键词:应急柴油发电机组,高温水循环泵,抗震试验:固有频率
中图分类号:TM623
文献标识码:A
文章编号:1001-4357(2017)05-0041-05
Seismic Test Research of Auxiliary High Temperature Water Circulating Pump
forEmergencyDieselGeneratorSetsinNuclearPowerStation
Sun Zhihong',Zheng Zhongwei’,Li Pengtao
(1. Shaanxi Diesel Engine Heavy Industry Co., Ltd., Shaanxi Xingping 713105 :
2. China Nuclear Power Engineering Co., Ltd., Beijing 100840;
3. Power System Engineering Company, Shaanxi Diesel Heavy Industry Co., Ltd., Shaanxi Xian 710077) Abstract: According to the relevant national standards, seismic test was carried out to verify the perfor mance of auxiliary high temperature water circulating pump for emergency diesel generator set in one nu-clear power station. The natural frequency and damping ratio of high temperature water circulating pump has been measured using white noise signal as input excitation. According to the specific position of the high temperature water circulating pump, the corresponding earthquake response spectrum was selected, and 5 times of operation basis earthquake tests and 1 time of safe shutdown earthquake test were carried out. The results show that the high temperature water circulation pump has enough anti-seismic intensity, and able to run normally under the conditions of prescribed seismic conditions, thus could meet the seis-mic requirements.
Key words: emergency diesel generator set; high temperature water circulating pump; seismic test; natural frequency
0引言
地震情况下,核电站的内部电源有可能发生断
电故障,此时反应堆堆芯内产生的大量热量如果得不到及时有效的冷却,将可能导致堆芯融化甚至爆炸,后果极其严重。因此在核电站的设计中必须要
收稿日期:2017-06-06
作者简介:孙志宏(1970-),男,高级工程师,主要研究方向为核电站1E级应急柴油发电机组生产与科研,E-mail:sumzhihong@sxdlinfo.com.e
上一章:高强度螺栓的监控扭矩研究 下一章:某四缸柴油机排气歧管开裂故障分析

相关文章

核电站水压试验泵柴油发电机组鉴定方法研究 NB/T 20485-2018RK 核电厂应急柴油发电机组设计和试验要求 NB/T 20129-2012 压水堆核电厂核岛应急柴油发电机组的安装、试验与验收技术规程 核电站应急柴油机润滑油系统温度高故障分析 核电站应急柴油发电机组缸套异常磨损分析与改进 NB/T 20449-2017 核电厂应急柴油发电机组燃油系统设计准则 核电厂应急柴油发电机1E级励磁系统设计探讨 NB/T 20423-2017 核电厂移动式应急柴油发电机组调试技术导则