您当前的位置:首页>论文资料>往复压缩机强制冷却系统的设计及应用

往复压缩机强制冷却系统的设计及应用

资料类别:论文资料

文档格式:PDF电子版

文件大小:198.05 KB

资料语言:中文

更新时间:2025-01-08 14:15:46



推荐标签:

内容简介

往复压缩机强制冷却系统的设计及应用 往复压缩机强制冷却系统的设计及应用张利
(中石化洛阳工程有限公司,河南洛阳471003)
使用维修 Semice&Ma
[摘要]:通过对强制冷却系统的设置,阐述了对气缸、填料冷却的作用与好处,讨论了冷却系统供水压力的设定和加热
器的选用型式,为冷却系统的设计、节能降耗及节约投资提供参考。[关键调]:压缩机;强制冷却系统;水系出口压力;加热器
中图分类号:TH457文献标志码:B 文章编号:1006-2971(2016)05-0053-03
DesignandApplicationofReciprocatingCompressorForcedCoolingSystem ZHANGLi
(Lauoyang Petrochemical Engineering Corporation Ltd.,Luoyang 471003,China)
Abstract:Based on the setting of forced cooling system, the functions and advantages for cylinder and packing cooling was specified and the setting of water supplied pressure for cooling system and the selection type of heaters were discussed in the paper. It pro-
vides references for the design of cooling system, energy=saving and consumption reducing and saving investment. Key words:compressor; forced cooling system; outlet pressure of pump; heater
1引言
随着国民经济不断增长的变化趋势,石油化工工业的产能迅速上升,往复压缩机是炼油装置中的重要设备,在石油化工领域的应用中无处不在。作为装置中的关键设备,为了机器能够长期、稳定的运行,减少不必要的停机及经济损失,本文对往复压缩机强制冷却系统的设计及应用进行探讨。
强制冷却系统的作用 2
往复压缩机在工作过程中介质被压缩、活塞杆运动通过填料时的摩擦,以及活塞、活塞环与气缸壁的摩擦都会产生热量,要带走这些热量,就要进行充分的热交换,因此设置强制冷却系统的作用如下。
2.1控制冷却水温度
由于工艺介质往往在40℃时处于饱和状态,而炼厂的冷却水温度多为25~30℃,此时采用装置的收稿日期:2016-08-16
■2016年05期(总第259期)
循环水进行冷却会在气缸壁处产生冷凝,凝液受到压缩力后会对气缸产生冲击,导致气缸损坏,甚至撞缸导致事故。API618要求气缸冷却水的温度应高于介质入口6℃,这样可以避免过度的冷却。 2.2防止冷却水结垢
装置的循环水未经特殊处理,容易结垢,易造成堵塞,破坏冷却效果,特别是填料冷却水的循环水路窄而且细,采用强制冷却系统提供的除盐水进行冷却可以解决这个问题。
3强制冷却系统的组成 3.1水箱
水箱是用来储存冷却水、提供冷却水和回收冷却水的,其材质一般选择碳钢,为防止锈蚀会在水箱的内部做防腐处理。水箱上设有补水口、放气口、人孔、排污口、液位计、温度表和加热器。
冷却水一般采用装置除盐水即可,在寒冷地区的冬季,可在除盐水中添加适当比例的乙二醇以防止冻结。
压编机技术53 Compressor
上一章:压缩机的现状、发展及新型技术展望 下一章:膨胀阀特性对压缩机性能测试精确度影响的实验研究

相关文章