2012年第12期(总第180期)
doi:10.3969/j.issn.10093230.2012.12.009
应用能源技术
暖通系统用能指标核查及合理性诊断
高春旭,李永涛”,黄家铭
31
(1.黑龙江省技能技术服务中心,哈尔滨150001;2.审计署哈尔滨特派员办事处,哈尔滨150001)
摘要:文中简单介绍对暖通设备现场诊断其能耗的一种方法,通过对各种参数按照观察、交流、节能测试、计算等步骤,然后判断其问题所在并解决问题。对系统的诊断可由工程的实施阶段和维护运行过程中的各类问题给出量化的分析结果,从而知道和展开节能减排工作的进行。
关键词:暖通;节能;诊断
文献标志码:B文章编号:1009-3230(2012)12-0031-03
中图分类号:TV832.1.1
TheResolutionofEnergyConsumptionIndicatorsVerification
andReasonablenessHVACSystem GAO Chun-xu',LI Yong-tao',HUANG Jia-ming
(1.Energy Conservation Service Center of Heilongjiang Province,Harbin150001,China;
2.CommissionerHarbinAuditOffice,Harbin150001,China)
Abstract:The paper introduces a method of the diagnosis in energy consumption to the HVAC equipment on the spot investigation, with analyzing the features of the calculation parameters such as observation-question, test-calculation, identification-resolution, assessing the crux of the problem and solving the problem. Based on analysis of the system in execution stage of the project and the questions in the service automatic movement process, results of these analysis for different schemes are given, in order to give guidance and overall consideration to the work of conserving energy and reducingemissions.
Key words: HVAC; Energy saving; Resolution
0引言
暖通系统的能源消耗取决于负荷需求的大小,包括满足建筑舒适性要求的冷热量供应、满足人们读书写字需要的光照和排除污染物满足热源健康需要的新风。系统运行效果和故障诊断应首:先着手于合理的负荷要求,重点考察三方面的内容,包括维护结构的保温隔热性能、室内排热量处
理、新风量的提供和满足情况。 1节能诊断(OTI)
所谓OTI,也就是只该诊断方法的如下几个收稿日期:2012-11-10修订日期:2012-1128 作者简介:高春旭(1968-),男,毕业于大连铁道学院热能
动力专业,现从事节能方面研究与测试工作。
万方数据
环节:
观察——交流(Observation-question)测试——计算(Test-calculation)
判断——诊断(Identificationresolution)
各诊断步骤相互关联,但不存在固定的先后顺序,可依照被测试系统的具体情况,测试所在的季节和测试人员的力量,有侧重点的灵活展并。 2用能指标核查和符合需求合理性
诊断
既有建筑的节能诊断,首先应了解系统功能、面积、使用情况等相关信息,并根据已有用能记