48
doi:10.3969/j. issn. 1009 3230.2013.07.013
应用能源技术
2013年第7期(总第187期)
高温地热水供热系统关键技术研究
张铭
(中国平煤神马集团环境保护部,河南,平顶山467000)
摘要:主要从优化理论的角度出发,分析了深层地热高温水供热系统的几种关键技术设备。即高温热泵、换热器和风机盘管等关键技术的概念、分类、运行条件等进行了研究。以便于科研、设计、运行管理等科技人员决策参考使用。
关键词:高温地热;供热系统:关键技术
中图分类号:TU822.2文献标志码:B
文章编号:10093230(2013)07004803
ResearchonKeyTechnologyofHighTemperatureHotWater
HeatingSystem ZHANG Ming
(Pingdingshan of chnia Group Environmental Protection Department, Pingdingshan 467000,chnia ) Abstract: This article mainly embarks from the optimization theory, analyzes the key technology and equipment of several deep geothermal hot water heating system. High temperature heat pump, heat exchanger and fan coil and other key technology concepts, classification, operation conditions were studied. In order to facilitate decision-making scientific research, design, operation and management of science and technology personnel.
Key words: High temperature geothermal; Boiler system; Key technology
0引言
在我国,低温地热资源占地热能总量的98% 以上。目前,全国地热资源直接利用总量已达到 2410MW,居世界各国前列,但利用水平和效率比较低,对于25~50℃温度段的能量利用率很差。为实现地热资源的可持续发展,国家制定了“十五能源发展战略规划”,要求调整能源结构,减少燃煤造成的污染,大力开发可再生能源,其中提到了利用热泵技术来充分利用低温地热资源。地热作为一种清洁能源,可实现建筑供暖,低温地热资源利用主要需解决的三个问题是:
(1)为实现低温地热资源的梯级利用,必须
修订日期:20130524
收稿日期:2013=05-11
作者简介:张铭(1984-),融理工程师,本科,毕业于平顶山
工学院环境工程专业,现供职于中国平煤神马集团环境保护部从事节能和环境治理技术工作
万方数据
对温度在40℃左右的地热尾水温度加以利用。
(2)对一些温度在55℃左右的高温地热田,其能量品位低,不能直接作为散热器末端供暖。
(3)减少因地热尾水排放所造成的热污染和地面沉降等间题。
对于40℃左右的地热水,普通热泵无法利用,因常温热泵的蒸发器进水温度不能超过 21℃,否则会因蒸发压力过高导致压缩机烧毁;常温热泵冷凝器的出水温度不能超过55℃,否则也会因冷凝压力过高导致压缩机烧毁。此外,建筑供暖系统的末端形式主要有风机盘管、散热器等,设计供暖温度都在60℃以上,因此,实现地热水的梯级利用必须使用高温热泵技术。
1高温热泵技术 2.1高温地源热泵的概念
高温地源热泵的高温"是相对于目前占市