2018年第7期(总第247期)
doi:10. 3969/j. issn. 1009 3230.2018. 07.014
应用能源技术
空气源冷热水热泵系统关键技术实验研究
陈志杰,刘彩赢
(珠海格力电器股份有限公司,广东珠海519070)
摘要:以低环温空气源户式地暖机组为对象,对采用变频压缩机的空气源冷热水热泵系统在低温环境下的启动性能进行试验研究。实验结果表明,经过低温环境长期放置的热乘机组,首次上电启动过程中,系统存在抽真空现象,造成蒸发侧压力过低使得系统出现低压保护而启动失效。可通过结合压缩机启动初始频率及节流元件的初始开度,保证机组在低温环境低水温顺利启动,其研究结果可为产品开发提供参考。
关键词:变频压缩机;启动性能;空气源冷热水热泵
中图分类号:TU831.3
文献标志码:B
文章编号:1009-3230(2018)07004504
Experimental ResearchonKey Technology of Cool-hotWater
Air-sourceHeatPumpSystem
45
CHEN Zhi jie, LIU Cai ying
(Refrigeration Institute of Gree Electric Applicances,Zhuhai 519070, Guangzhou Province, China.)
Abstract:This paper presents the experimental research on starting performance of cool hot water air source heat pump system with inverter compressor in a household floor heating central air conditioning unit under low temperature condition. The results show that the vacuum pumping was observed when the heat pump unit electrified after long term placement in low - temperature environment. The system failed to start up because of the low voltage protection caused by the excessive low of evaporating pressure. The heat pump unit can be started up by measuring the initial starting frequency of the compressor and the initial operting of the throttling devices. The conclusions obtained in this paper can provide guidance for product development.
Key words: Inverter compressor; Starting performance; Cool -hot water air source heat pump
0引言
自空气源热泵机组诞生以来,因其利用可再生能源空气能、高自动化程度、系统简单、安装便利等特点,广泛应用于国内外。时至今日,空气源热泵按使用温度范围可分为低温型及常温型两大类。近些年,随着城镇化的不断推进以及气候变化的影响,在我国一些处于法定供暖区域但却没法实现集中供的郊区、独栋别墅,包含一部分非
收稿日期:20180528
修订日期:2018=06=10
作者简介:陈志杰,男,工程师,学士,研究方向为低温热泵
系统。
万方数据
法定采暖区域,对使用低环温空气源热泵采暖的需求越来越强烈,究其原因是低环温空气源热泵能在低温的环境下仍保持着较好的制热能力及运行可靠性,而目前市场上常规的空气源热泵机组在低温环境下运行效率较低,甚至无法使用。据相公开的文献资料及相关资料显示,不少工程人士及国内外学者对低环温空气源热泵都进行了多方面的研究。纵观此类公开文献资料,在制冷系统流程方面进行分类,可分为采用喷气增熔压缩机的准双级压缩闪蒸器二次节流系统1-4'的实验研究与双压缩机双级中间不完全冷却系统(5-7)