18
doi;10.3969/j. issn.1009 3230.2017.07.006
应用能源技术
2017年第7期(总第235期)
浅谈燃机电厂防爆电气设备隐患整改
羹晓晓
(中山嘉明电力有限公司,广东中山528437)
摘要:介绍了燃机电厂爆炸性设备环境、危险等级及其隐患,针对这些隐惠进行相应的整改,从而达到AQ3009-2007危险场所电气防爆安全规范的要求,确保然气发电及氢气冷却发电机组的安全运行。给同类型机组对防爆隐患的排查及整改,提供了参考。
关键调:燃机电厂;危险区域;防爆;隐惠整改
中图分类号:TM621.7+1文献标志码:B文章编号:10093230(2017)07-0018-04 IntroductiontoHiddenDangerRectificationofAnti--Explosion
ElectricalEquipmentinGasPowerGeneration
GONG Xiao-xiao
(Zhongshan Jiaming Power Limited Company,Zhongshan 528437,Guangdong Province,China) Abstract: Gas turbine power plant is introduced with explosive device environment, risk degree and its hidden trouble. According to these hidden dangers, the corresponding rectification is done, which can achieve AQ3009 dangerous sites 2007 electric explosion proof safety specification require-ments, and ensure that the gas power generation and hydrogen cooling generator safety. That can provide the reference of the screening of explosion hazards for the same type unit rectification.
Key words: Gas power generation; Dangerous district; Anti explosion; Hidden danger rectification
0引言
目前,我国燃机电厂主要承担调峰作用,它的电气部分具有与燃煤机组不同的特征,燃机电厂在生产中使用燃气发电及氢气冷却发电机组,在作业现场,包含甲烷和氢气两种危险气体,分属于IIA类和IIC类易燃易爆气体。因此在燃机电厂生产区域划分中将制氢单元、氢气汇流分配单元、氢气密封油系统、氢气纯度测量单元、天然气调压站、燃气加热单元、燃气轮机本体及管道阀门所在罩壳区域定为爆炸性气体环境,依据各种要素综合考虑,危险等级定义为2区,将危险气体排放管道出口处定义为1区,危险等级更高。
收稿日期:20170510
修订日期:201705-21
作者简介:费晓晓(1976-),男,工程师,主要从事发电厂生
产设备检修维护和技术改造等生产管理工作。
万方数据
由于燃机电厂爆炸性气体环境1区在排放管道出口处位置较高,且周围无电气设备,所以平时维护工作很少。在爆炸性气体环境2区内包含很多热工专业和电气专业的电气设备,其中热工专业的电气设备数量较多,主要是测温、测压元件、行程开关,危险气体探头等测量元件,还有少部分 110V直流或220V交流驱动的电磁闵,电气专业设备主要包括电机、加热器、灯具、电源开关几种设备。关于电气设备防爆的研究,吴远志[2]提出了燃气电厂在建设、运营过程中电气防爆管理需要关注的问题。朱洪江3研究了当前燃气企业电气设备管理现状并提出了提高燃气企业电气设备管理水平的措施。高风荣[4]研究了燃气-蒸汽联合循环发电机组的电气设计,对电气主接线、控制方式、继电保护和二次接线等方面进行了重