第30卷第3期
2010年
9月
核科学与工程
Chinese Journal of Nuclear Science and Engineering 中国实验快堆三废控制系统
李禾1,李晓薇2
(1.中国原子能科学研究院,北京102413;2.中国核电.工程有限公司,北京100840)
Vol.30 Sep.
No.3 2010
摘要:介绍了中国实验快堆及三废系统的组成和必要性,国内商用核电站三废系统运行情况。介绍国家标准、法规对核电站三废系统设计的要求,对三废系统贮存、排放废气、废液的要求。利用图形方式介绍
中国实验快堆的三废控制系统功能和结构特点。关键词:三废;以太网;P1L.C
中图分类号:TL.32
文献标志码:A
文章编号;0258-0918(2010)03-0234-04
Thethree wastes control system of CEFR
LI He', LI Xiao-wei?
(1, China Institute of Atomic energy; Beijing 102413, China;
2, China Nuclear Power Engineering Co, , Ltd, , Beijing 100840, China)
Abstract:The paper describes the composition and importance of three wastes control system of China Experimental Fast Reactor (CEFR), and operation of the three wastes control system of some commercial nuclear power plant in China, The paper also intro-duces requirements of national standards, laws and regulations on the design of the system, and on the storage and discharge of gaseous and liquid wastes from the system. Finally, the paper introduces the functional and structural characteristics of the three wastes control system of CEFR.
Key words:three wastes; ethernet; PLC
任何一座核电站都存在三废间题。如何贮存、处理和排放,它关系到工作人员及周边数十平方公里内的环境和公众的生活和安全问题。中国实验快堆(ChinaExperimentFastReac tor,CEFR)三废控制系统由放射性废液暂存及转运系统(E01);放射性固体废物暂存及转运
收稿日期:2010-05-14修国日期;2010-08-24
系统(E02);放射性废气排放系统(E03);乏燃料贴存水池冷却系统(D02);乏燃料水池净化系统(D07);乏燃料水池检漏系统(D08)组成。在工艺上它们是6个独立的系统,目的是对中国实验快堆运行时产生的三废进行储存处理,并对三废进行贮存量的监测。
作者篇介:李禾(1956一),男,浙江诸暨人,高级工程师,从事可毫性和自动控制研究 234