中国实验快堆失去厂外电后单台主泵
停运的一回路瞬态特性分析
任丽霞,王晋,胡文军
(中国原子能科学研究院快堆工程部,北京102413)
摘要:失去厂外电源是在中国实验快堆(CEFR)运行寿期内可能多次发生的预计运行事件。本文基于自主研发的系统瞬态分析程序FASYS分析了CEFR失去厂外电源后单台主泵停运的事件,并将事件过程中的关键参数与试验结果进行了对比。通过试验和模拟分析,得到了中国实验快堆失去厂外电源后单台主泵停运的一回路瞬态特性。
关键调:中国实验快堆;失去厂外电;FASYS
中图分类号:TL364
文章标志码:A
文章编号:0258-0918(2016)01-0035-07
StudyforCEFRPrimaryCircuitTransientPerformanceinCase
of One PrimaryPumpTrip duringLoss of Off-sitePower
REN Li-xia,WANG Jin, HU Wen-jun(China Institute of Atomie Energy, Beijing 102413, China)
Abstract: Loss of off-site power test is one of anticipated operational occurrences of China Experimental Fast Reactor.In the paper,the transient was simulated and analysed by FASYS code, which was developed by ourselves, and comparisqn between the test and theoretic results was carried out. The paper illustrated the transient performance of CEFR primary circuit in case of primary pump trip during loss of off-site power.
Keywords;fast reactor;loss of off-sitepower;FASYS
1引言
失去厂外电源是在中国实验快堆(CEFR)运行寿期内可能多次发生的预计运行事件。失修回日期:2015-07-21
去厂外电源事件发生后,“失去厂外电”紧急停堆保护信号触发反应堆紧急停堆,一、二回路主循环泵和三回路给水泵失去正常供电自然情转,两路应急柴油发电机启动分别带载两台一
作者简介:任丽霞(1978—),女,山西城人,副研究员,反应堆工程专业