2011年3月下第40卷
第337期
施工技术
CONSTRUCTIONTECHNOLOCY
钢绞线加固混凝土梁的试验与研究
刘明泉
(唐山学院土木工程系,河北唐山
063000)
【摘要】对既有建筑物的抗震加固和节能改造是一项重要的工程。用钢绞线加固混凝土结构是一种新型的加固方法。对两组钢筋混凝土梁进行试验研究,对比分析加固前后聚的开裂荷载、届服荷载、极限倚载和破坏形态的变化情况。试验结果表明,加固架的承截力明显提高。最后,在试验的基础上,给出了可用于工程设计的极限受弯承截力的计算公式。
【关键调】钢绞线;混凝土结构;加固;极限受弯承载力
【中图分类号】TU746.3
【文献标识码】A
【文章编号】1002-8498(2011)06-0081-03
ExperimentandStudyonConcreteBeamReinforcedbySteelWires
Liu Mingquan
(Department of Civil Engineering,Tangshan College, Tangshan,Hebei 063000,China)
Abstract:Seismic strengthening and energy saving reinforcement is an important engineering of existing buildings. Reinforcing concrete structure with steel wires is a new method. Two groups of beams are tested, the cracking load,yield load and ultimate load are compared between strengthened and un-strengthened beams. The test result shows that bending capacity of reinforced beams raise obviously Finally, based on experimental study, the formula of ultimate bending capacity which can be used in engineering design is presented.
Key words:steel wire; concrete structure; reinforcement; ultimate bending capacity
既有建筑物抗震加固和节能改造已成为我国政府正在进行的一项重要民生工程,而这其中绝大部分既有建筑物需要进行这两方面的改造工程。采用钢绞线加固混度土结构的方法在国内外都尚处于初步研究阶段,作者以试验研究为基础,结合理论分析,得出加固梁的正截面极限受弯承载力计算公式。 1试验设计
本次试验共设计了8根钢筋混凝土试验梁,分为2组,每组4根:①对比梁B1,加固粱J1-1,加固梁J1-2;加固粱J1-3;②对比粱B2.加固粱J2-1.加固梁J2-2,加固梁J2-3。加固前架的各参数均相同:截面尺寸为6×h=150mm×300mm,跨度l=3200 mm,净跨l。=3000mm,混凝土保护层厚度为 25mm。所有的梁在试验前均无受荷历史。
第1组试验架按照少筋架制作,加固梁在梁底补配钢绞线。为避免在正截面破坏前斜截面先发生破坏,加密剪弯段箍筋。第2组试验梁按照适筋梁
【收稿日期】2010-11-15
【作萬介】刘明泉,房山学院上本工程系安验审主任,讲师,康山市路北区华北路38号
063000,电话:13363365656,E-mail;Imq.
1009@sina.com 万方数据
81
制作,加固梁所用的抗弯钢绞线面积为第1组加固梁的1/2,筋按最小配箍率P...ic=0.24f./f,= 0.15%设置。梁在加固前按所用材料强度的实测值计算得到的斜截面受剪承载力为67.6kN,为防止余截面受剪承载力不足的情况发生,预先在剪弯段附加了U形箍筋。
B1,J1-1,B2,J2-1的尺寸和配筋如图1所示,B1 截面配筋率为p=0.25%
镀锌钢绞线U形箍。 2试验材料
1)混凝土及钢筋
采用C25商品混凝土,
HPB235钢筋。
2)钢绞线
试验中采用Φ'3.6高强镀锌钢绞
线,其抗拉强度标准值为1370N/mm,抗拉强度设计值为970N/mm,实测抗拉强度可达到1432N/ mm,柔韧性较好,并兼顾防腐的要求。在加固施工过程中,需要对钢绞线进行适当预张拉。