2002版与2010版《混凝土结构设计规范》
钢筋用量比较分析杨虹,阳丹,伍平
(西华大学建筑与土水工程学院,四川成都
610039)
【摘要】通过2002版与2010版(混凝土结构设计规范》的对比,从混凝土保护层厚度、受拉钢筋的错固长度、织向受力钢筋的最小配筋率、受剪承载力、考虑重力二阶效应的偏心受压构件公式等5方面介绍了规范涉及对钢筋用
量的变化,并说明两版规范的异同为工程设计带来的影响。【关键调】规范;混凝土:锅筋
【中图分类号】TU755.3
[文献标识码]A
【文章编号】1002-8498(2012)10-0091-04
ComparisonofCodesforDesignofConcreteStructures onReinforcementAmountBetween2002and2010Edition
Yang Hong,Yang Dan,WuPing
(School of Building and Ciril Engineering,Xihua University,Chengdu,Sichuan610039,China)
Abstract;Through the comparison of Codes for design of concrete structures between 2002 and 2010 Edition,the change of reinforcement amount in two codes are introduced from concrete cover thickness, anchorage length of tensile reinforcement and minimum reinforcement ratio and shear capacity of longitudinal tensile reinforcement and eccentric compression members considering the gravity second-order effect. It concludes that the differences between two editions have an influence on the construction design.
Key words:codes; concrete; reinforcement
从建国到现在,混凝土结构设计规范的制订经历了照搬照抄的CBJ21-66规范、自主制定的 TJ10—74规范、跨越式发展的GBJ10—89规范、实施全面与国际接轨的GB50010—2002规范(简称 2002版),以及2011年7月1日开始实施的 CB50010—2010规范(简称2010版)等5个发展阶段。最新颁布的2010版《混凝土结构设计规范》,相对2002版面言,主要增加了500MPa级带助钢筋,以300MPa级光圆钢筋取代235MPa级钢筋,修改了受剪承载力计算公式,调整了混凝土的保护层厚度、钢筋的锚固长度和纵向受力钢筋最小配筋率等内容,这些均涉及钢筋用量的调整,引起工程建设相关人员的普遍重视,尤其是开发商。因此,本文就混凝土保护层厚度、受拉钢筋的锚固长度、纵
[收璃日期】2011-11-16
【基金项目】西华大季校级精品课程(xjipke0909)
【作著简介】杨虹,四华大学建筑与土木工程季院副教授,四川省成都市金牛区西华大学建筑与土木工程学院
610039,电话:
13808060662,Email;545948032@ qq.com 万方数据
91
向受力钢筋的最小配筋率、受剪承载力和考虑重力二阶效应的偏心受压构件等方面探讨了对钢筋用量的变化。
1混凝土保护层厚度
在2002版《混凝土结构设计规范》中混凝土保护层厚度是指:纵向受力钢筋的外表面到截面边缘的垂直距离;在2010版中指:结构构件中钢筋外边缘至构件表面范围,如图1所示。两版规范在定义方面的主要差别在于2010版除了钢筋的定语“纵向受力"4个字。说明2002版仅关注对受力纵筋的保护,10版关注对各种类型锅筋的保护,既有纵筋也有箍筋,保护范围扩大。具体对梁、柱构件而言,由纵向钢筋和箍筋组成,保护层厚度的改变影响了正截面设计中截面有效高度h。=h-a,的计算(布置排钢筋时,2002版a,=c+d/2,2010版 g,=c+d+d/2,见图1)其中,a,为织向受拉钢筋合力点到截面受拉边缘的距离,而h。的改变直接影响了梁、柱构件钢筋含量的增幅。对板构件而言,由纵向受力钢筋和分布钢筋组成,保护层厚度